Ancar TOPCON ATE-800 Інструкція з експлуатації - Сторінка 10
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Внутрішнє оздоблення приміщень Ancar TOPCON ATE-800. Ancar TOPCON ATE-800 13 сторінок. Ophthalmic table
11.- MAINTENANCE
Surfaces of the table can be cleaned by a cotton piece dampened with water and neuter soap.
Dry up immediately. Do not splash with water or any other liquid. Do not blow spray cleaner
directly into the unit. It could travel through a clearance around the switches and cause
electrical problems. A fire or electric shock may occur as a result.
You must never clean with alcohol, abrasive or chemical products!
If table does not operate, may be that motor thermal had actuated (after continuous
operation), in that case wait for its reestablishment. Furthermore:
-Check supply voltage according to the table model: 230Vac (± 10%) 50/60Hz (±1 Hz).
-Check if power cord has come out of the outlet. Insert the power plug securely.
-Check main switch status. Turn it on.
-Check if fuses have blown out.
Before replacing or checking fuses, make sure power switch is turned off and power cord has
been removed from the outlet. If fuses have blown out, use the specified rated values.
If after a certain time any anomaly persists, call the technical service!
In the event of a smoke comes from the table, immediately turn off the power switch and
remove the power plug from the outlet.
Make sure fixation bolts are tightened securely. When a bolt becomes loose, tabletop may lay
off, causing the table to tip over or loaded equipment to fall off and caused an injury.
12.- SPECIFICATIONS
Technical Features
Concept
Total Power
Maximum Consumption
Electrical classification
Electrical protection degree
Maximum overload of instruments on tabletop
Maximum overload on PC holder
Maximum overload on Printer support
Stroke
Horizontal displacement
Net weight / Gross weight
Duty cycle (on/off) tabletop elevation motor
Fuses (consumable part)
Electrical Safety
In order to use with a completely safety, the equipment disposes of the following protection
elements:
Concept
Protection against electric shock
Maneuver voltage
Electrical classification
Rigidity of transformer
Motor overload protection
Failure power supply
Short circuit protection
Plug connection
Auxiliary outlets
Subject to change in performance and / or appearance without prior notice for future improvement.
220-230 Vac / 50-60 Hz
1.300 VA
Class I, Type B
80 Kg.
15 Kg.
10 Kg.
350 mm.
Casters.
38.2 kg. / 47.5 kg.
1/29 minutes
2 x F6.3A / 250V
Earth connection, Class I Type B
12Vdc (Very Low Safety Voltage)
Class I, Type B
Separated winding isolation 3,9 Kv
By thermal protector
Stationary equipment
By fuses (see electric diagram)
Previous earth connection
4 outlets up to 850 VA
10
IP21
QS4-423-01