6. Dip Switch
DIP Switch settings for Single Loop (LDP1)
Selection
1
mode
2
Channel
selection
3
4
Turn-on delay
5
ASB
6
Failure mode
7
Output mode
8
Time
9
Entry / Exit
10
Output mode
11
Time
12
Entry / Exit
DIP-switch 1 - Selection mode: The loop detector operates on one out of four channels.
Depending on the noise sources in the vicinity (other loop detectors/frequency converters/starters
etc. i.e. crosstalk) can it be helpful to choose a channel where the loop detector is not disturbed by
the noise. The loop detector will indicate by a white flash which channel the loop detector are using
after power up.
Set DIP SWITCH 1 to OFF
measure the noise levels on all channels and automatically select the channel with the least noise. This
will be done once every time the loop detector is powered up.
Set DIP SWITCH 1 to ON
,2 ,3 or 4.
12
Rev.00 - 09.2018 | LDP1/LDP2 Single and Dual Loop Detector | © 2018 | CARLO GAVAZZI Industri
ON
Frequency settings
Automatic channel selection
DIP switch 2 and 3 are not used in
automatic channel selection
General settings
Delay OFF
ASB OFF
Fail safe
Relay 1 settings
Pulse mode
0.1 sec pulse
0.5 sec pulse
Vehicle entry
Relay 2 settings
Pulse mode
0.1 sec pulse
0.5 sec pulse
Vehicle entry
for automatically selection During startup will the loop detector
for manual selection Use dip switch 2 and 3 for selecting channel 1
1
Infinite
Vehicle exit
Infinite
Vehicle exit
Manual channel selection
2
3
Delay 2.0 sec
ASB ON
Fail secure
Presence mode
60 min
10 min
Presence mode
60 min
10 min
4
1 min
1 min