Athena RMB/2 Короткий довідник

Переглянути онлайн або завантажити pdf Короткий довідник для Регулятор температури Athena RMB/2. Athena RMB/2 2 сторінки. Non-modular hot runner temperature controllers

Athena RMB/2 Короткий довідник
OPERATING YOUR CONTROLLER
Assuming that all zone power and thermocouple are
1)
correctly in place, turn on the controller using the power
switch on the back. The controller will complete its
startup sequence, and the process value and setpoint for
every zone (the standard operating display) are shown.
All zones will be Idle (all outputs off ).
If the controller has already been wired to the sensors
If the controller has already been wired to the sensors
and heaters, do NOT push the run/idle
until after you have confi gured the zones and entered
customsetpoints.
When zones are taken out of Idle, their outputs may go
on (check default parameter values).
Take unneeded zones out of service by setting them
2)
to Offl ine.
a) Select a zone by pressing the zoneselection button
until only that zone's PROC and SETP are displayed.
(Zone numbers are shown next to the row of status LEDs
for eachzone.)
b) Access the mode-selection function by pressing the
Access the mode-selection function by pressing the
mode/ enter button
.
c) Step through the possible modes by pressing
the mode/enter
button repeatedly until "Offl ine" is
displayed.
d) Exit the mode-selection function by pressing the
Exit the mode-selection function by pressing the
menu- access/exit button
. A confi rmation will be
displayed briefl y and then the PROC and SETP for the
zone will be displayed as"OFF."
The green F (for Fahrenheit) or C (for Celsius)
3)
LED is lit; indicating the scale being used. If you want to
change the temperature scale:
a) With any zone selected, press and hold the menu-
With any zone selected, press and hold the menu-
access/ exit button
until the name of a confi guration
menu is displayed.
b) Step through the menus by pressing
repeatedly until the Display Confi g menu name is
displayed.
c) To access the Display Units parameter, press
The scale will alternate with the parameter name on the
lower line of the display. An asterisk is displayed instead
of a zone number to indicate that the parameter applies
to allzones.
d) Press
or
to change the temperature
scale
e) Exit the menu system by pressing and holding
for several seconds and the PROC and SETP for all
zones (except any offl ine zones) will be displayed in the
new selected scale. Any temperature values previously
entered will be converted automatically.
button
A row of LEDs for each zone indicates statuses for the zone and its output. These status icons are:
lit green when the zone's output is on
output:
boost:
lit green when the zone is in Boost mode
closed loop:
etc.
open loop:
standby:
alarm:
flashes red when the zone is in alarm
Buttons provide access to all controller functions. The purposes of the buttons are shown below.
Zone selection button -
the zone selection button is redundant and
removed.
Silence alarm button - silence time is con-
fi gurable
Apply Boost to all zones selection button
Idle mode selection button - press for at
least two seconds to put all zones in idle
mode
lit green when the zone is in a closed loop mode, such as Normal, Closed Loop Boost, Normal Soft Start,
lit green when the zone is in an open loop mode, such as Manual or Open Loop Boost
lit green when the zone is in Standby mode or Hardware Standby mode
on the RMB/1
NOTE
Increase setpoint and upward scroll
through parameter values button
Decrease setpoint and downward scroll
through parameter values button
Mode and Menu item selection button
Mode display. Press longer to enter Menu
selection.