Test 2: Measurement of the 10 MHz Sine Wave Output in the Presence of Motor Noise
1
Figure 2 – Experimental Setup for the Measurement of a 10 MHz Sine-wave Output in the
1. Supply a 5 V input voltage to the EMI Source Module.
2. Switch S5 to the 'ON' position to turn on the 10 MHz Sine Wave Oscillator.
3. Use a digital oscilloscope to probe test point TP11 with respect to GND, which is the output of
the 10 MHz Sine Wave Oscillator. You should observe a pure sinusoidal waveform.
4. Next, switch S4 to the 'ON' position to turn on the brushed DC motor. Observe the output of
the Sine Wave Oscillator in the presence of motor noise. Describe the differences as
compared to the observations made in Step 3.
5. Switch S4 and S5 to the 'OFF' position.
6. Connect the output of the 10 MHz Sine Wave Oscillator (J8) to the RF In port of the N9912A
FieldFox RF Analyzer using an RF coaxial cable.
7. Power on the N9912A FieldFox RF Analyzer.
8. Set the N9912A FieldFox RF Analyzer to operate in the Spectrum Analyzer mode. Select the
start and stop frequencies, and other settings according to the following configuration:
Mode
Start Frequency
Stop Frequency
N9912A Setting: "[ ]": Hardkey; "{ }": Softkey
Set Mode to SA measurement: [Mode] > {SA}
Set Start Frequency to 5 MHz: [Freq/Dist] > {Start} > [5] > {MHz}
Set Stop Frequency to 15 MHz: [Freq/Dist] > {Stop} > [15] > {MHz}
Set output power level to LOW: [Meas Setup 4] > {Output Power} > {Low}
Scale: [Scale/Amptd] > {Autoscale}
Perform Calibration: Normalization
ME1400 EMI and EMC
4
Presence of Motor Noise
: SA
: 5 MHz
: 15 MHz