Carmanah EG320 Посібник користувача - Сторінка 6

Переглянути онлайн або завантажити pdf Посібник користувача для Освітлювальне обладнання Carmanah EG320. Carmanah EG320 13 сторінок. Eg-series
Також для Carmanah EG320: Посібник користувача (16 сторінок)

EG320/EG340 Programmer

The programmer is used to program the EMS with
the correct operating profile for your application. The
programmer is also used to test the EG320/EG340
system to confirm correct operation. The programmer
is powered by two AA batteries (not included), and
communicates with the EG320/EG340 EMS using
two-way infrared signals.
The programmer has two buttons: Send and Test. The
Send button is used to upload the operating profile
(parameters) to the EG320/EG340 EMS, while the
Test button is used to test that the EG320/EG340
system is operating correctly.
The 12 knobs and switches on the programmer
come pre-configured with the correct settings for your
application. If the knobs or switches get moved acci-
dentally, return them to the positions indicated by the
faceplate label.
The EG320/EG340 uses two-way
NOTE
communication between the
programmer and EMS. Therefore
each EG320/EG340 EMS must
be programmed one at a time.
Problems arise when more than
one EMS is in range during
programming.
6
The programmer has indicator lights and a beeper
to convey status to the user. The following table
summarizes the meanings of the lights and the
beeper:
Feedback
Three short beeps & green OK
light ~5s after pressing/holding
Send button
One long beep & red Error
light ~5s after pressing/holding
Send button
One short beep after pressing/
holding Test button
One long beep & red Error light
immediately after pressing Test
or Send button
© 2015, Carmanah Technologies Corporation. EG320-340_UserManual_76116RevA
EG320/EG340 USER MANUAL
EG 300 PRoGRAMMER
Status
Programming successful
Programming not successful
Test command transmitted
Replace 2 X AA batteries in
programmer