SPECIFICATIONS
Model No.
Indication of BAC
Sensor
Warm up time
Response time
Recovery time
Accuracy
Working
Temperature

DEVICE FEATURES

The ALX3000 can be used with various settings to suit the user. The default settings are as follows:
1. Service and Calibration period is 365 days.
2. If the test result is "PASS", then you have 5 minutes to start the engine.
3. If the test result is "FAIL", the next test can be performed only after 5 minutes.

OPERATING INSTRUCTIONS

1. Insert a mouthpiece into the ALX3000 handset.
2. Turn on your vehicle ignition.
3. Press the "Enter" button on the handset to start the device. When it displays "Perform breath
test", you will hear a beep sound.
4. Wait until the device finishes warming up.
5. When the device is ready for a breath test it will display "BLOW".
6. Take a deep breath, place your lips completely around the mouthpiece, and blow steadily into it.
7. The breath sample will be analysed, and the result will be displayed.
8. If you pass the breath test, then a countdown will follow, allowing you to start your car within
this time frame.
9. If you fail, a temporary lock-out will follow, and the vehicle will not be able to start.
Note: If the amount of alcohol detected is above the set limit value, a "FAIL" message appears
on the display and a different alarm sound is produced for each alcohol concentration:
- LOW level: 3 "beeps"
- HIGH level: 1 long "beep" for 10 seconds
After the alarm, the ALX3000 will automatically lock for 15 minutes, and retests are not
permitted during this time. The next test-able time will count down and can be confirmed on the
display. All events are recorded within the ALX3000.
ALX3000
0.000% - 0.400%BAC
Fuel Cell Sensor
5-60 seconds
Within 10 seconds at
0.10%BAC
10-30 seconds
±0.005%BAC at
0.100%BAC
-40 – 85°C
Memory
Device: 500 test records
Control Box: 500,000 test
records
Mouthpieces
5 pieces included
Calibration
Every 1 year
Operation
DC 12 ~ 24v
Voltage
Weight
Handset: 135g
Control Box: 650g
Dimensions
146 x 60 x 28 mm
Warranty
1 Year
3