Andea Electronics TPAD20 M Посібник користувача - Сторінка 13

Переглянути онлайн або завантажити pdf Посібник користувача для Зчитувач штрих-коду Andea Electronics TPAD20 M. Andea Electronics TPAD20 M 14 сторінок. Rfid reader machine

5.1.4. Trigger options
Close RF when free: In the host control mode, the machine will automatically
turn off the radio frequency when it does not receive the command of card
reading or opening the RF
Read buzzer: When the buzzer on the board is on, tick the Read Buzzing to turn
on the read buzzer. At this time, the buzzer will buzz when reading the tag.
5.1.5. Hardware switch
Open buzzer on-board: Whether to turn on the buzzer on the board.
Close anti-collision function: turn off the anti-collision function.
Send antenna ID: Whether to upload the antenna interface number when
Guangzhou Andea Electronics Technology Co., Ltd.
http://www.gzandea.com
User's manual
14/18
Guangzhou Andea Electronics Technology Co., Ltd.
http://www.gzandea.com
Working mode of the system can be divided into host mode and scan mode:
Host mode: Controlled by the host software.
Scan mode: take the initiative to scan and send the scanned data to the host.
Among them, when choosing the working mode as the scan mode, configure the
parameters of the scan mode:
Set the start address of the data block to be
Data block start address
scanned.
Number of blocks scanned
Set the number of blocks to be scanned
Set whether to scan the serial number of the
Scan the serial number of the tag
tag.
Scan data block
Set whether to scan the tag's data block
Output in original
The hexadecimal characters scanned are
value
output in hexadecimal format
Scan
Output in ASCII
results
code
after
being
output
The hexadecimal characters scanned are
converted
into
format
output in ASCII character string format
hexadecimal
character
1. Use the system separator
Separator type
2. Use user-defined separators
Carriage return& line feed 0x0D + 0x0A,
line feed 0x0A, carriage return 0x0D, TAB
Separator
System's separator
0x07, semicolon 0x3B, comma 0x2C, space
0x20.
Customized
Set a custom separator value, which falls
separator
within 0x00-0xFF
Ending
character
1. Use the System's ending character
type
2. Use the Customized character
Carriage return& line feed 0x0D + 0x0A,
Ending
System's
ending
line feed 0x0A, carriage return 0x0D, TAB
character
character
0x07, semicolon 0x3B, comma 0x2C, space
0x20.
Customized
Set a custom terminator value, which falls
character
within 0x00-0xFF
User's manual