ANDELI TIG-250PL ACDC Посібник оператора - Сторінка 12
Переглянути онлайн або завантажити pdf Посібник оператора для Інвертор ANDELI TIG-250PL ACDC. ANDELI TIG-250PL ACDC 20 сторінок. Inverter ac/dc pulsed tig welder
Power factor
Max no-load voltage(V)
Adjustment
range
of
start current(A)
10~welding current
Adjustment
range
of
welding current(A)
Adjustment
range
of
Crater arc
current(A)
Adjustment
range
of
downslope time(S)
Pre-gas time(S)
Adjustment
range
of
post-gas time(S)
Clearance effect(%)
Efficiency
Duty cycle
Protection class
Insulation class
Dimensions of Machine
(mm)
(L×W×H)
Weight(Kg)
3.2 Duty cycle & Over heat
The letter "X" stands for duty cycle, which is defined as the proportion of the time that a
machine can work continuously within a certain time (10 minutes). The rated duty cycle means
the proportion of the time that a machine
can work continuously within 10 minutes
when it outputs the rated welding current.
The relation between the duty cycle
"X" and the output welding current "I" is
INSTALLATION AND ADJUSTMENT
AC
HF
LIFT
30~welding
current
10~200
30~200
10~200
30~200
AC
25% 200A
60% 129A
100% 100A
X
100%
25%
10
0
0.76
64
TIG
DC
10~welding current
10~200
10~200
0~5
0.1~1
0.1~10
15~50
IP21S
H
380*206*274
12.6
The relation of the welding current and
duty cycle for WSME-200
100
DC
25% 200A
60% 129A
100% 100A
200
I(A)