ATI Technologies 39-0080 Посібник з експлуатації - Сторінка 15

Переглянути онлайн або завантажити pdf Посібник з експлуатації для Вимірювальні прилади ATI Technologies 39-0080. ATI Technologies 39-0080 15 сторінок. Milk meter

Innovation In and Out of Parlour
Milk Meter Fault Finding Scheme
Micro Wash / MM Hub Control Faults
Symptom
Micro wash control lid / MM Hub fault
Stand-alone/Master wash control not
putting milk meters into wash mode
Slave wash control / MM Hub not putting
milk meters into wash mode
Wash cycle too long/too short
15 | Milk Meter Service Manual | v1.2
Possible Cause
Display fault
Keyboard fault
Individual LCD dead
Wiring connection fault
Software Crash
Master/slave setting incorrect
Wiring connection fault
Control address setting incorrect
Master/slave setting incorrect
Wiring connection fault
Micro M3S / M5 not communicating
Wash time set too long/too short
Solution
Change control lid.
Change control lid.
Check wiring in connection box.
Check wiring in control box.
Check power supply, mains fuse, plug fuse and
output fuse.
Un-plug lid; then plug in again.
Check master/slave setting correct.
Check wiring connections in wash control lid.
Check wiring connections in connections box.
Check control address settings.
Check for duplicate control addresses.
Check master/slave setting correct.
Check wiring connections in wash control lid.
Check wiring connections in connections box.
Check connections to Micro M3S / Micro M5.
Check all milk meter controls communicating.
Change wash time.