MODEL A76 CONTROL
NOTE: Use 18–22 AWG wire for control wiring.
A Model A76 Control must be wired to the
dehumidifier for external control:
1. Turn off power to the dehumidifier at the
fuse or breaker until wiring is completed.
2. Run a 3-wire thermostat cable (use 18–22
AWG wire) from the Model A76 to the
electrical panel of the dehumidifier.
3. Trim about 1/4" of insulation from the end of
the wires on each end. Insert a small blade
screwdriver into the square opening next to
the desired terminal in the dehumidifier to
open the clamping spring of the terminal.
Insert the wire and remove the screwdriver to
catch the wire. At the Model A76 secure the
wires into the terminals and tighten the cage
screws. See FIGURE 15.
4. Use extra wire to make a small jumper to
wire between the R/+ terminal and one of
the DH terminals of the Model A76 Control.
The Model A76 will measure the relative
humidity and turn the dehumidifier on and off to
control the humidity level to the desired setting.
The humidity setting can be adjusted from the
control while the display allows easy access and
monitoring of the humidity level in the space. It
is recommended that the Model A76 be mounted
at/near canopy height.
Press the ON button on the Model A76 to turn
on the control. The UP/DOWN arrow buttons
are used to set the desired humidity setting. At
all other times, the Model A76 will display the
measured humidity level. Reference the Model
A76 Installation Instructions and Owner's Manual
for set-up.
ALTERNATE EXTERNAL CONTROLS
A Model 8840 thermostat can be used to control
the HVAC equipment, and for dehumidifier
control in place of the Model A76. The
Model 8840 thermostat has Wi-Fi capability.
Additionally, up to four remote sensors can
be mounted near the canopy and connected
to a single thermostat. The four humidity
measurements can be averaged and the
thermostat will turn on the dehumidifier based
on the averaged value.
Reference the 8840 Installation Instructions and
Owner's Manual for set-up and operating details.
8
FIGURE 15 – MODEL A76 WIRING
5-POSITION TERMINAL BLOCK IN
DEHUMIDIFIER ELECTRICAL PANEL
1 2 3 4 N
R/
NOT
DH
C
DH
USED
MAKE A SMALL JUMPER AND PUT IT IN
THE R/+ AND ONE OF THE DH TERMINALS
FIGURE 16 – MODEL 8840 WIRING
CONTROL MODULE OF MODEL 8840 THERMOSTAT
INSERT A SMALL FLAT BLADE SCREWDRIVER
TO OPEN THE WIRING LATCH. INSERT THE
WIRE AND RELEASE THE LATCH TO COMPLETE.
MODEL A76 CONTROL
A
B
C/-
R/+
DH
DH
INSERT A SMALL FLAT BLADE SCREWDRIVER
TO OPEN THE WIRING LATCH. INSERT THE
WIRE AND RELEASE THE LATCH TO COMPLETE.
1 2 3 4 N
R/
NOT
DH
DH
USED
5-POSITION TERMINAL BLOCK IN
DEHUMIDIFIER ELECTRICAL PANEL
C