Electrolux A 75279-4 GA Посібник користувача - Сторінка 11

Переглянути онлайн або завантажити pdf Посібник користувача для Морозильна камера Electrolux A 75279-4 GA. Electrolux A 75279-4 GA 16 сторінок. Electrolux freezer

Problem
The Pilot light flashes.
The Alarm light flashes.
The compressor operates
continually.
The temperature in the
freezer is too low.
The temperature in the
freezer is too high.
A large quantity of drops
ice covers the top com-
partment inside the ap-
pliance.

Closing the door

1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "Installation".
3. If necessary, replace the defective door gaskets. Contact the Service Force Center.

Cleaning the evaporator

1.
Switch off the appliance.
Possible cause
The appliance is not working
properly.
The temperature in the freezer is
too high.
The temperature is not set cor-
rectly.
The door is not closed correctly. Refer to "Closing the door".
The door has been opened too
frequently.
The product temperature is too
high.
The room temperature is too
high.
The FROSTMATIC function is
switched on.
The temperature regulator is not
set correctly.
The FROSTMATIC function is
switched on.
The temperature regulator is not
set correctly.
The door is not closed correctly. Refer to "Closing the door".
The product temperature is too
high.
Many products are stored at the
same time.
Products are too near to each
other.
There is too much frost and ice
on the evaporator of the appli-
ance, the door was open for too
long time.
What to do if...
Solution
Contact a qualified electrician.
Refer to "High temperature
alarm"
Set a higher temperature.
Do not keep the door open longer
than necessary.
Let the product temperature de-
crease to room temperature be-
fore storage.
Decrease the room temperature.
Refer to "FROSTMATIC function".
Set a higher temperature.
Refer to "FROSTMATIC function".
Set a lower temperature.
Let the product temperature de-
crease to room temperature be-
fore storage.
Store less products at the same
time.
Store products so that there is
cold air circulation.
Refer to "Cleaning the evapora-
tor".