to the faulty controller will be affected. The other units in the system will
continue to operate normally. The DIP switch settings are as follows:
• DIP SWITCH 1 ON: 4 seconds
• DIP SWITCH 2 ON: 8 seconds
• DIP SWITCH 3 ON: 16 seconds
Be certain that only one DIP switch is turned ON at any time. All others should
be left in the OFF position.
Master/Local Selection and System Configuration
The XRD-8050 must be user-configured for MASTER or LOCAL operation.
DIP switch settings and an overall system configuration diagram are as follows:
For MASTER Operation: Set DIP Switch 1 and 3 OFF, 2 and 4 ON
For LOCAL Operation: Set DIP Switch 1 and 3 ON, 2 and 4 OFF

Optical Fiber Compatibility

Various versions of the XRD-8050 will successfully operate with most multi-
mode or single-mode optical fibers. These versions are as follows:
XRD-8050-1
XRD-8050-3
XRD-8050-7
XRD-8050-8
Multimode 62.5u Fiber
Multimode 62.5u Fiber
Single-mode 8/10u Fiber
Single-mode 8/10u Fiber
• DIP SWITCH 4 ON: 32 seconds
• DIP SWITCH 5 ON: 64 seconds
• DIP SWITCH 6 ON: Disabled
850nm
1300nm
1300nm
1300nm
7
ST Connector
ST Connector
FCPC Connector
SMST Connector