Modules can be arranged side by side in row, each row can run separately, or it can be
ignited by flame propagation. If flame propagation section is configurated, the pilot burner
should be in the bottom of the burner and flame monitor be at the top end of the burner.
Burner frame, flame retainig plate, nozzles are all made of stainless steel. Gas fuel supplied
to nozzles through gas manifold. Combustion air or process air goes through the slots in
the flame retaining plate to mix with gas. VFC86 burner could be assembled separately
according to special requirement. Bracket used for fixing burner or duct. As flow is adjusted
by the control valve. Main fire is ignited by pilot burner, please refer to pilot burner
description for more information. Process air pressure switch used to detect pressure drop
of the burner.
VFC86 Series Burner Advantage:
– A turndown over 10:1 is generally obtainable across the full burner matrix without the
need to isolate burner rows. This enables the burner to meet changing heat demands
while maintaining uniform distribution across the duct area.
– Modular design, each model size is 150 mmX150 mm, could be assembled according to
different requirements.
– Stable flame and low NOx emission, even the process air pressure drop across burner
is 1mbar, the burner can also keep stable flame, so make sure low NOx emission to
realize clean combustion. This is achieved by swirling the exhaust gases into the gas jets.
The swirling also cools the module material.
– Reliable operation performance, once commissioning is complete, it is stable under the
same condition, no need for extra adjustment or maintenance.
– Burner suit for different gas fuel such as natural gas, LPG or hydrogen.
– Operation in high temperature, as all the material of the burner is stainless steel, burner
could run with high process temperature of
6. Burner Component Introduction
VFC86 burners are mainly made up of frame, flame retaining plate, gas nozzle and gas
supply manifold. For different parts, they are connected by rivets or bolts to make up
burner body. Burner diagram shown in Fig 1
Anderson Thermal Soluions(Suzhou)Co., Ltd
Anderson Thermal Solutions – VFC86 Burner Operation Manual
750°C.