Community dSPEC Посібник з усунення несправностей підключення - Сторінка 11

Переглянути онлайн або завантажити pdf Посібник з усунення несправностей підключення для Обладнання для запису Community dSPEC. Community dSPEC 20 сторінок.

3. Verify Ethernet cable connections

The Ethernet jack is on the back of dSPEC. Verify that both ends of the Ethernet cables are securely latched and
you have a known working Ethernet cable.

4. Verify dSPEC power connections and heartbeat

Verify the heartbeat light on the front of dSPEC is blinking.
If the dSPEC heartbeat light is not blinking, please contact Community. Additionally, you can try cycling power on
the unit.
Verify the power cord is securely connected on the back of the dSPEC and to the power outlet. Verify the power
outlet has power.

5. Cycle power on the dSPEC(s) (turn off amps first)

Turn off any amps that are connected to the output of the dSPEC(s).
Remove power from the dSPEC(s). dSPEC does not have a power switch – so do this by switching off the power
source or unplugging the dSPEC power cord.
Reapply power to the dSPEC(s).
Turn on any amps that were turned off above.
P a g e
| 11