Comnet CLFE4+1SMS[POE](C Посібник з монтажу та експлуатації - Сторінка 8

Переглянути онлайн або завантажити pdf Посібник з монтажу та експлуатації для Мережевий маршрутизатор Comnet CLFE4+1SMS[POE](C. Comnet CLFE4+1SMS[POE](C 10 сторінок. 10/100 4tx+1ex ethernet self-managed switch with power over ethernet (poe+)

Comnet CLFE4+1SMS[POE](C Посібник з монтажу та експлуатації
INSTALLATION AND OPERATION MANUAL

APPLICATION NOTES

1
Mixed PoE and Non-PoE systems can be implemented.
2
Lower data rates generally provide longer operating distances.
TABLE 3 – APPROXIMATE MAXIMUM EXTENDED DISTANCES
Media
Extended Port Data Rate
Extended Distance
1
Distance figures are obtained using in-house testing mirroring installations. Factors such as coaxial/copper cable quality, the number of connectors/
1
splices in the cable run, the use of PoE, and environmental conditions encountered within the installation may affect the actual transmission
distance, and should be taken into consideration.
TABLE 4 – TROUBLESHOOTING GUIDE
Problem
Indicating LEDs not lighting
No Communication
Bad Video
Units not reaching estimated max
distances over COAX or UTP
Not all cameras visible
TECH SUPPORT: 1.888.678.9427
COAX - RG59/U
10M
100M
5,000 ft
2,000 ft
1,524 m
610 m
Steps to Take
Check that power is properly applied to the unit using the correct connector pair.
Check Ethernet Link LEDs, Extended Link LEDs, All Connections, Local/Remote switch is set properly.
Verify that Local units are installed at the head end and that Remote units are installed in the field.
Verify that the Data Rate switches are set to the same data rate on both the Local and Remote units.
Make sure Data Rate and 1/4 Pair Switches are set properly, and the extended distance is within specifications (see Table
3 – Approximate Maximum Extended Distances).
Check extended distance cable and connections. Try connection on a short cable to eliminate possibility of faulty cabling.
Check that the extended distance wire is connected to Extended Distance Port.
Verify that there is no additional equipment (e.g. surge protector) on the Extended Link. The cable should be continuous from
end to end, with no active components.
Check that the Managed/Unmanaged DIP switch is set to "Managed."
1
UTP - 1 pair
10M
100M
3,000 ft
1,000 ft
914 m
305 m
CLFE4+1SMS[POE](C,U) SERIES
UTP - 4 pair
10M
100M
3,000 ft
2,000 ft
914 m
610 m
INS_CLFE4+1SMS[POE](C,U)_REV– 10/27/11 PAGE 8