Comnet CopperLine CLFE8IPS Посібник з монтажу та експлуатації - Сторінка 14

Переглянути онлайн або завантажити pdf Посібник з монтажу та експлуатації для Перемикач Comnet CopperLine CLFE8IPS. Comnet CopperLine CLFE8IPS 19 сторінок. High-power poe mid-span injector

Comnet CopperLine CLFE8IPS Посібник з монтажу та експлуатації
INSTALLATION AND OPERATION MANUAL
Overload Counter
Shows how many times the port has been in overload status.
Short Counter
Shows how many times the port has been shorted.
Power Denied
Counter
Shows how many times the port has denied power to loads.
Invalid Detection
Counter
Shows how many times the port has been detected an invalid load.
Commands
Disable
Disables the port. Buttons "Disable", "Enable" & "Force Power" are mutually exclusive.
Enable
Enables the port. Buttons "Disable", "Enable" & "Force Power" are mutually exclusive.
Force Power
Forces the port to turn on power. This will bypass detection, classification and power
management checks. No violation will be honored. Buttons "Disable", "Enable" & "Force
Power" are mutually exclusive.
Reset Statistics
Resets all port statistics.
Apply
Applies the user selected configuration on to the selected port.
Tech SupporT: 1.888.678.9427
CLFE(X)IPS
INS_CLFE(X)IPS_REV–
12/15/11
PAGE 14