10 electrolux
3. With a socket spanner 7 remove the in-
jectors and replace them with the ones
which are necessary for the type of gas
you use (see table in "Technical Infor-
mation" chapter).
4. Assemble the parts, follow the same
procedure backwards.
5. Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
this plate in the package supplied with
the appliance.
If the supply gas pressure is changeable or
different from the necessary pressure, you
must fit an applicable pressure adjuster on
the gas supply pipe.
ADJUSTMENT OF MINIMUM LEVEL
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum posi-
tion.
3. Remove the knob.
4. With a thin screwdriver, adjust the by-
pass screw position.
A
A) The by-pass screw
• If you change from natural gas G20 20
mbar to liquid gas, fully tighten the by-
pass screw in.
• If you change from liquid gas to natural
gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn (1/2 of
a turn for Triple Crown burner).
Warning! Make sure the flame does
not go out when you quickly turn the
knob from the maximum position to the
minimum position.
ELECTRICAL CONNECTION
• The electrical work necessary to install
the appliance must be done by a quali-
fied electrician or competent person, ac-
cording to the current regulations.
• The appliance must be earthed.
• Always use a correctly installed shock-
proof socket.
• Make sure that there is access to the
mains plug after the installation.
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains
plug.
• The appliance must not be connected
with an extension cable, an adapter or a
multiple socket. There is a risk of fire.
Make sure that the ground connection
complies with the standards and regula-
tions force.
• The power cable must not touch any hot
parts.
• The electrical installation must have an
isolation device which lets you discon-
nect the appliance from the mains at all
poles. The isolation device must have a
contact opening width of minimum 3
mm.
• You must have the correct isolation devi-
ces: line protecting cut-outs, fuses
(screw type fuses removed from the
holder), earth leakage trips and contac-
tors.
• The connection cable parts must not be
heated to a temperature above 90°C.
Electrical Requirements
Permanent electrical installation must com-
ply with the latest I.E.E. Regulations and lo-
cal Electricity Board regulations. For your
own safety the installation must be done by
a qualified electrician (e.g. your local Elec-
tricity Board, or a contractor who is on the
roll of the National Inspection Council for
Electrical Installation Contracting [NICEIC]).
The manufacturer declines any liability
if these safety measures are not ob-
served.
The appliance must be connected to a 230
V 50 Hz AC electrical supply.
Before activating the appliance, make sure
the electrical supply voltage is the same as
that indicated on the rating plate. The rating
plate is located on the bottom of the appli-
ance.
The appliance is supplied with a 3 core flex-
ible supply cord with a 3 amp plug. If it is
necessary to change the fuse, use a 3 amp
ASTA-approved (BS 1362) fuse.