Compac Master MR400S Інструкції зі встановлення та налаштування - Сторінка 5
Переглянути онлайн або завантажити pdf Інструкції зі встановлення та налаштування для Водяний насос Compac Master MR400S. Compac Master MR400S 18 сторінок.
Static Electricity Precautions
3.
Electronic components used are sensitive to static. Please take anti-static precautions.
An anti-static wrist strap should be worn and connected correctly when working on any
electronic equipment. If an anti-static wrist strap is unavailable, or in an emergency, hold onto
an earthed part of the pump/dispenser frame whilst working on the equipment. This is not a
recommended alternative to wearing an anti-static wrist strap.
Note: Compac Industries Limited reserves the right to refuse to accept any circuit boards
returned, if proper anti-static precautions have not been taken.
Pre-installation Check
4.
Once the pump is received on site, check that no damage has occurred while in transit – in
particular, damage to electronics due to vibration or jarring. All terminals and plugs should be
checked, including IC chips, to ensure they are securely in place.
5.
Installation
Installation should be in accordance with local regulations.
The dispensing equipment shall be installed to prevent the delivery hose from contacting the
ground when not in use.
Where local regulations require a sump to be fitted:
a. Sumps must be provided at all dispenser installations with secondary containment pipework
and at all new installations; and
b. at all sites with sumps, dispensers should be installed with a liquid level detection device
fitted in the sump that will raise an alarm if liquid is detected in the base of the sump.
Important Note: Compac M400 high flow dispensers do not have an internal filtering system
fitted at the factory. It is the customer and/or installers responsibility to ensure the fuel supplied
to the dispenser is clean and free from any dirt, debris or metal particles that could damage the
meter or hydraulic components. A 10 micron filter is recommended. Compac does not warranty
the meter or hydraulic components for damage caused by contaminated fuel supply.
Comms Dip-switch settings
6.
Standard Pump Comms Setting
6.1
(Dipswitch SW3)
1-ON
2-OFF
3-ON
4-OFF
These are factory set to the standard setting unless ordered otherwise.eg Gilbarco.
Gilbarco Pump comms Setting
6.2
(Special software and interface board required)
1-OFF
2-ON
3-OFF
4-ON
G:\Masters\Installation Sheets\Master & Premier\MR400S Installation Sheet.doc
Page 5 of 18