Setup example
> >
Mode button being pressed to scroll through menu. This set up is for a kitchen, in a through the wall
installation with 15 minute boost timer, 60% rH set point and not in comfort mode.
Mode and up buttons pressed to change the setting to Bathroom and ducted modes
Pull Cord Function
Pulling the pullcord will activate boost 1, a second pull will enter boost 2 and a third pull will
cancel the boost, returning the fan to trickle speed. The pullcord can be used to cancel an LS
activated boost, if the fan is in an LS activated boost pulling the pullcord will first enter boost a
further pull will return the fan to trickle.
Data Logger (ACR60 model)
With the fan powered up; upon removing the cover the display will automatically activate. It
will display the commissioning options. Holding down the Mode button for 5 seconds will open
the data logger menu. Use the mode button to move the display to the next data set.
Data Logger Menu
* When the display is rotated the decimal point will no longer display; eg. 055 represents 5.5KWh
Display text
tot run 00y 00d
Tri run 00y 00d
Boo run 00d
rhu run 00d
tot EnErgy 00.0
24h EnErgy 00
X
>
> >
+
> >
+
Up button pressed to change boost time from 15 to 18 minutes
Pull
Boost 1
> >
X
>
X
> >
X
> >
+
Pull
Boost 2
Description
Total run time in years and days
Trickle speed run time in years and days
Boosted run time in days
Humidity boosted run time in days
Total Energy used displayed in KWh*
Energy used in last 24 hours displayed in Wh
> >
X
> >
+
> >
+
Pull
Boost Off