Compact Instruments Advent Series Інструкція з експлуатації Посібник з експлуатації - Сторінка 6
Переглянути онлайн або завантажити pdf Інструкція з експлуатації Посібник з експлуатації для Вимірювальні прилади Compact Instruments Advent Series. Compact Instruments Advent Series 7 сторінок. Digital optical tachometer
4. Linear contact speeds measurement - metres, yds, feet etc.
4.1.
Fit contact adaptor as above.
4.2.
Keeping the on button pressed, now place the contact wheel on the moving surface and
read the linear rate, ensure wheel is vertical to the moving surface.
4.3.
Releasing the on button will then hold the last reading in the display
for 1 min.
4.4.
The instrument retains selected measurement mode for further linear measurements af-
ter switch off until programmed to a different mode.
5. Autorange selection - speed modes only
5.1.
While taking a measurement using either up or down measure button, the user can tog-
gle between auto and non-auto mode by pressing the programme button, in the auto
mode, the a icon will illuminate.
6. Average speed monitoring mode - '
6.1.
Average speed mode - this mode provides a rolling average of the last 8 measured val-
ues.
6.2
Press and hold the On/off button at the forward arrow position and hold continuously
6.3
Aim light beam onto target, ensure "on-target" sign is on at bottom of display screen.
6.4
Take rpm reading.
6.5
Note that the display will illuminate only while measurement is taking place.
6.6
Release on/off button and display will clear - no memory retention is available.
7. Operation of Maximum & Minimum modes Speed Capture functions - mx,mn.
7.1.
Having selected the required mode, i.e. Maximum or Minimum, (mx).
7.2.
You are now ready to Capture a reading "On Demand" but continuing to operate normally.
7.3.
When a capture test is ready to commence, while the Measure button is held On, press
Programme button once, at this point the instrument will switch into high speed Timebase
mode, (0.1 Seconds) and will Capture the highest or lowest reading after pressing the
Programme button.
Releasing the On button will hold the reading and cancel the Capture mode until another
Capture measurement is required, when 7.3. should be repeated.
8. Count measurement mode - cnt
8.1.
Select mode as described in Measurement mode selection section
8.2.
For rev Counting optically, point the light beam at the target and the instrument will
measure all revs. (pulses) until button is released, the display will hold Count for 1
minute.
8.3.
By contact method, fit contact adaptor, press speed cone onto the end of the shaft, the
Instrument will count revs.
9. Linear Length Totalisation measurements - mt, ft, yd -
9.1.
Select any linear unit of measurement, press contact wheel onto moving surface and
commence Count by pressing & holding Measure button On, Count will increment until
button is released.
9.2.
The displayed value can be scanned through the equivalent values of Metres, Feet,
Yards, Count by pressing the Programming button, the instrument automatically calcu-
lates the appropriate reading.
Note. Measurement Units will be stored in originally programmed parameter e.g. metres.
av'
icon.
Page 7