Atlantic F17 Посібник з експлуатації - Сторінка 4

Переглянути онлайн або завантажити pdf Посібник з експлуатації для Обігрівач Atlantic F17. Atlantic F17 5 сторінок.
Також для Atlantic F17: Документація по встановленню та використанню (6 сторінок), Посібник (13 сторінок)

Atlantic F17 Посібник з експлуатації
1) Description of the control unit :
(marche/1) /
switch (stop/0).
2) Fixing the comfort temperature
The comfort temperature is the temperature that you would like while the room is occupied.
a) Put the
switch to ON (marche/1).
b) Set the
control knob to between 4 and 5. Electronic Model : the heating indicator V1 comes on if the room
temperature is below the required temperature.
c) Wait a few hours for the temperature to stabilise.
d) If the setting is satisfactory (if necessary use a thermometer to check), mark the position for future use.
e) If the setting is not satisfactory, adjust it and start again from point c.
3) Frost-Free mode
This mode is used to keep the temperature at approximately 7°C in the room when you are absent from the house for
a prolonged period (i.e. more than 24 hours).
a) Leave the
switch on
b) Set the
control knob to
4) The heating indicator : V1 (electronic model)
This light comes on when the heating element is working. It may flash when the temperature has stabilised.
5) Locking the controls : 7 7 7 7 7
It is possible to lock or limit use of the
the panel heater (children, etc.).
a) Unhook the panel heater from its wall mounting.
b) Remove the slugs P on the back of the thermostat from their mountings.
c) Select position B to lock the control knob or position L to limit the amount it can be turned. Position M blocks the switch
for Electronic Model.
6) Using the pilote wire
The product with pilote wire can receive the following signal from a master unit :
- COMFORT (Temperature of
- ECO (Comfort temperature -3°C to 4°C)
The product must be connected through the pilote wire to a programming control or a product with K7 Program
in order to use comfort or eco mode. You can thus control several convectors with a single programmer or a product
with K7 Program.
- There is no point in setting maximum heating, the room temperature will not rise any quicker.
- When you air the room, disconnect the panel heater by putting the
- If you leave for several hours, remember to reduce the temperature.
Absence for :
- If you have several units in a room, let them operate simultaneously. This will give you a more uniform temperature
without increasing electricity consumption.
This appliance is not intended for use by young children or infirm persons without
supervision. Young children should be supervised to ensure that they do not play
with the appliance, lean against the front or insert objects or paper in it. Do not
totally or partially block the grilles on the front or inside of the appliance, as this
may cause overheating. If the supply cord is damaged, it must be replaced by a
service agent or similarly qualified person in order to avoid a hazard (applies to
units fitted with a supply cord and plug). Units fitted with a three core supply cord
(brown, blue & black), must be directly connected to fixed wiring by a licensed
electrician. All work on the interior of the appliance must be carried out by a licensed
electrician.
USING THE PANEL HEATER
5 5 5 5 5
6 6 6 6 6
and
Temperature adjustment control knob.
/I.
.
(mecanical)
8 8 8 8 8
et
control knob and lock the
control knob)

RECOMMENDATIONS FOR USE

less than 2 hours, do not touch the controls.
2 to 24 hours, lower the
control knob by two graduations.
more than 24 hours or in the summer, put the
the
on
(electronic).
WARNINGS
V1
Heating indicator light
switch to prevent unauthorised manipulation of
switch to
/ 0.
control knob to
(mecanical),