Before You Start

• Check the model name plate to make sure once again that the product
is of the correct voltage and frequency rating.
• The setting on the circuit breaker or other overload protector should
be made in accord with the rated currency of the pump.
• Turn off the power supply or circuit breaker before inserting the power
supply plug to avoid electrical shock, shorting, or unexpected starting
of the pump, which could lead to injury.
• Never operate the pump while it is suspended in air. The recoil may
result in injury or other major accident.

Electrical Safety

• Electrical wiring should be installed by a qualified electrician in accor-
dance with all applicable safety regulations. Incorrect wiring can lead
to a pump malfunction, electrical shock or fire.
• Pumps should operate on a designated, 110 volt circuit rated at
15 Amps (minimum).
• Pump must be protected by a ground fault circuit interrupter (GFCI).
• Pump must be plugged into a standard, properly grounded, three
pronged outlet.
• Do not cut the electrical cable. If a cable with cut insulation or other
damage is submerged in water, there is danger of water seeping into
the pump motor and causing a short. This may result in damage to the
pump, electrical shock or fire. Altering the electrical cable in any way
will void the warranty.
• Never move or handle the pump by pulling on the electrical cable.
Make sure the electrical cable does not become excessively bent or
twisted, does not rub against a structure in a way that might damage it,
and does not come in contact with heated surfaces.

Operation

• In case of a power outage, turn off the power to the pump to avoid
having it start unexpectedly when the power is restored.
• Pay careful attention to the water level while the pump is operating.
Dry operation may cause the pump to malfunction. Pump must always
operate while fully submersed.
4