8.
If the DAD does not pass the test, leave this screen up when you
contact Technical Support as it will help them diagnose the issue
you are having.
a. Pass Example:
IMCLEAN DAD ERROR CODE STRING INFORMATION:
Code 0: Passed the test
Code 7 or 8:
• No devices detected. Please connect
one and retry.
o
Need to plug in IMClean USB cable;
repair Bluetooth.
• Firmware Error e7: efailed 'OpenDevice:
Cable not connected'
o
Need to plug in the proprietary
IMClean OBD2 cable
• [0201] No +12V test voltage available:
Expected > 8000mV, found #v
o
Need to plug in external power, using the
the IMClean External Charger or IMClean
Cigarette Lighter Cable
• [0202] Pin 16 voltage test FAILED:
expected > 11040mV, found ##LESS##
o
Need to plug in IMClean Self-Test Cable
• [0301] Pin 4 ground test FAILED:
expected 2650mV OC voltage,
found #m
o
Generally this indicates hardware damage.
o
Sometimes swapping 12v sources can
resolve this.
b. Fail Example:
• [0302] Pin 5 ground test FAILED:
expected 2650mV OC voltage,
found #m
o
Generally this indicates
hardware damage.
o
Sometimes swapping 12v
sources can resolve this.
• [0905] J1850PWM Remote Static Test:
Remote shows deasserted while local
TX asserted
o
Generally this indicates
hardware damage.
• [1002] K-Line Static Test: Idle state
voltage too low:
Expected > 10370mV, Found 160mV
o
Generally this indicates
hardware damage.
11