8. If the DrizAir 2400 shuts off for any reason, allow
five minutes before restarting to avoid compressor
damage.
Warning
If the unit is switched off during use, wait for five (5)
minutes before restarting. Attempting to re-start the
unit before this period of time may cause damage to
the compressor.
MAINTENANCE
Do not attempt to disassemble or repair a dehumi-
difier if you are not qualified to do so. Normal main-
tenance operations and troubleshooting solutions can
be handled by the technician in the field. More com-
plex problems should be handled by an authorized ser-
vice technician. See the Troubleshooting section.
Regular Maintenance
In order to maintain the DrizAir 2400 at optimum
efficiency and to prevent breakdown, the filter must be
cleaned or replaced regularly, and the evaporator and
condenser coils must be cleaned.
The coils are the means by which heat is transferred
between the air stream and the refrigeration circuit.
The coils are critically engineered so that the correct
heat transference takes place and the pressures within
the refrigeration circuit remain within operating limits.
The air passing through the DrizAir 2400 dehumi-
difier may be carrying considerable quantities of dust,
lint and fungus spores. Even using a filter, the coils
may pick up dirt and their heat transferring properties
decrease, resulting in reduced water extraction and un-
due pressure on the components. This is especially true
if the unit is operating in a dusty environment. For op-
timum efficiency, a maintenance schedule should be
set up for checking the coils and the filter at regular
intervals.
Cleaning or Replacing the Filter
Remove the filter from the filter shroud by inserting
a finger into the access hole at the top of the filter
shroud.
When using pleated paper filters, discard the dirty
filter and insert a clean one. If you have difficulty lo-
cating filters of the proper size, replacements are avail-
able from your local distributor. Call Dri-Eaz at 1
(800) 932-3030 for more information.
The DrizAir 2400 is equipped with a cleanable fun-
gal-resistant filter. To clean it use a light vacuum, or
wash with water and mild detergent. Spray directly
against the foam in the direction of the airflow. Begin
COPYRIGHT © DRI-EAZ PRODUCTS, INC. 1998
at the top of the filter and work down. Allow the filter
to drain dry before reinstalling it in the filter shroud.
Regularly clean or replace the air filter to avoid dam-
age to dehumidifier. Never operate without the air filter
in place.
Cleaning the Coils
The first step in cleaning the coils is directing com-
pressed air, from both sides, through the coils. Ideally,
the coils should be dry and the operation be completed
outside (because of the dust that may be created). After
blowing out loose contamination, a wet cleaning
process may be used.
A thorough cleaning of the evaporator coil can be
performed with an aluminum evaporator coil cleaner
available from a refrigeration service or supply outlet.
Follow the product directions carefully.
If you flush the coil, do not permit water to enter
the electrical compartment. Use a squirt bottle or a sy-
ringe so that you can control the water.
After cleaning the coils, ensure that the drain tray
and drain hose are completely free of dirt. Clean the
front grill with a vacuum cleaner and brush attachment.
Do not attempt to service or clean the dehumidifier
while it is plugged into an electrical outlet. It is dan-
gerous for an unqualified individual to attempt to dis-
assemble or repair the dehumidifier.
Electric Wiring & Cord
Inspect the power cord periodically to ensure insu-
lation is in good condition. Also inspect internal wiring
for abrasions, nicks or cuts. Repair or replace the elec-
tric cord or wiring as needed.
Remove the cover and ensure that all wires are se-
curely fastened and not discolored. (Loose connections
may heat up and show discoloration.) To inspect wir-
ing connections to the touch-pad controls, remove the
four control panel screws, and rotate the entire panel
backward toward you.
Pump Tube
Ensure that the pump tube is not kinked and in good
condition before the DrizAir 2400 leaves for the job
site and again after the installation is completed.
Pump System
Inspect and clean the pump system regularly to
maintain effective operation. Lay the DrizAir 2400 on
its back. The pump is located at the very bottom of the
7
Warning
Danger