AirTech AQ-40B Посібник користувача - Сторінка 6
Переглянути онлайн або завантажити pdf Посібник користувача для Трансивер AirTech AQ-40B. AirTech AQ-40B 6 сторінок. Fm handheld transceiver
can be configured for several different types of decode
operation. If a channel is selected that has Selcall
activated the radio will be muted until the proper signal is
received. When this occurs the radio can sound a ringing
type alert signal or a voice message maybe heard.
Depending upon the initial programming, pressing the
PTT may cause an automatic identifier to be sent. When
programmed for Selcall pressing the monitor and function
buttons at the same time can cause the Selcall mode to
be cancelled and generate an automatic identification.
Please have your radio technician or dispatcher fully
explain this operation.
Charger and Battery
1. Battery (Ni-Mh)
Voltage & Current
Duty time (5-5-90)
2. Charger
Input power
Operating temperature
Connect the charger to an appropriate outlet (120VAC
ADAPOR). Turn the transceiver power off and place the radio
into the front socket of the charger. The red light illuminates
during charging and the green light comes on when the
charge is complete. When you place two batteries in the
charger at the same time, the front battery will charge first.
The rear battery will begin charging when the front battery
charge is complete.
Red
On
Charging
Blinking
Abnormal battery
Green
On
Fully charged
Orange
On
Stand-by for charging (rear cup)
Blinking
Discharging
7
DC 7.5V , 1650mA
Over 8 hrs
CHARGER INPUT DA 12V
(120VAC)ADAPTOR
INPUT POWER
10-30 deg. C
When you put a battery in the rear cup of the charger the
charger checks the voltage. If voltage is over 7.4V, the
charger starts discharging for 4 minutes then checks
again. If voltage is still more than 7V, it discharges until
the voltage is 6V then starts charging.
8