Dri-Eaz DefendAir HEPA 500 Посібник користувача - Сторінка 2
Переглянути онлайн або завантажити pdf Посібник користувача для Очищувач повітря Dri-Eaz DefendAir HEPA 500. Dri-Eaz DefendAir HEPA 500 5 сторінок. Air scrubber
Також для Dri-Eaz DefendAir HEPA 500: Посібник користувача (6 сторінок), Посібник користувача (5 сторінок)
Fig. 2: Replacing the prefilters
Release the four spring clips (one shown here
and lift off cover to access the prefilter(s).
HEPA 500 APPLICATIONS
Water Damage
Use of the HEPA 500 within the affected area will reduce
particle levels during the restoration process. In a standard
Category 1 water damage situation, place the HEPA 500 in the
middle of the affected area. Category 2 and 3 water damage
situations may require negative pressure containment and
other precautions. Only professionals with the appropriate
training should use containment techniques.
Mold Remediation
Most mold remediation projects require containment.
Containment prevents the spread of mold spores and other
bioaerosols. Always use the optional DOP Filter (F415) when
using the HEPA 500 to ensure first-pass filtration in a
containment setup, Only a professional with the appropriate
training should attempt mold remediation.
Odor control
When used with the optional Activated Carbon Filter (F397),
the HEPA 500 can effectively remove many odors from an
indoor air environment, including volatile organic compounds
(VOCs), food odors, fumes from paint and paint thinners,
sewer odors, and many others.
Other uses include fire damage restoration, dust control, odor
control and sewage remediation. These are specialized
applications and require professional training. For more
information about using the HEPA 500 in these situations,
contact Dri-Eaz.
WARNING: BREATHING HAZARD
When using the HEPA 500 in a containment area,
turn off all sources of power to open combustion
appliances such as fireplaces, boilers, furnaces,
water heaters and HVAC systems to avoid the risk
of backdrafting deadly carbon monoxide fumes.
CONTROLS AND OPERATING
INSTRUCTIONS
Variable Speed Control knob
Increase the fan speed by turning the knob clockwise. Fan
speed can be adjusted between 250 and 500 CFM.
07-02068A F284-230V AU
Fig. 3: Replacing the HEPA filter
Remove the eight bolts and tabs (one shown here)
and lift off cover to access the HEPA filter.
Change Light
The change light illuminates when you need to change the
HEPA filter.
Setup
1. Unwrap the cord wrap completely
2. Place the HEPA 500 upright (vertical with handle at the top)
3. Plug in to a standard 230 volt outlet. Each HEPA 500 needs
1.5 amps to operate.
4. To switch the unit on, locate the control panel and turn the
variable speed switch clockwise (Fig. 1). Then select either a
maximum (500 CFM) or down to a minimum (250 CFM) airflow
rate. To maintain the optimal air change rate, consult the IICRC
S520 standards, 10.3.1.
Special Features
Ducting options
The HEPA 500 has a standard ductable 12 in. inlet and a
ductable 8 in. outlet, suitable for use with rigid and layflat
ducting. See "Ducting Options," p. 4, for descriptions of the
ducting types available from Dri-Eaz.
Negative Pressure Setup
The HEPA 500 can be configured to set up a negative
pressure containment area. Install the HEPA 500 outside the
containment area to draw air out. Only professionals with the
appropriate training should set up negative pressure
containment areas.
Options for Storage and Operation
The HEPA 500 can be stacked up to two high for storage or
operation. The handle of one unit fits snugly into the bottom of
a second unit. The unit can also be operated on its back, with
the outlet facing upward.
For storage, HEPA 500s may be stacked horizontally or
vertically. Secure the unit properly when transporting.
About the filters
The HEPA 500 uses two types of disposable filters: prefilters
and a HEPA filter. The prefilter section can be fitted with one or
two filters. These prefilters are designed to capture larger
airborne particles and to control odors, depending on the filter
selected. The HEPA section (Position 3), is fitted with a filter
designed to capture 99.97% of smaller particles down to 0.3
2