Disposal of Mercury Added Lamps
Germicidal ultraviolet lamps, like standard fluorescent lamps contain small amounts of mercury. Mercury added
lamps should not be placed in the trash. Dispose of properly. For further information regarding the disposal and
recycling of lamps containing mercury, along with Federal and State requirements visit LampRecycle.org. For more
information on STER-L-RAY
TROUBLESHOOTING
Always disconnect power to the water purifier before performing any service or maintenance.
IMPORTANT: This unit is to be serviced ONLY by qualified, and appropriately licensed, personnel.
Problem
Purifier not operating
Water leaking from purifier
Poor purifier disinfection performance
Ballast No. 10-0518A and 10-0514A have Lamp-out Protection
If power is applied to the ballast without a lamp connected to the circuit or if the lamp fails, the ballast's lamp-out protection
will prevent the ballast from operating, and a red LED light will illuminate and audio alarm will sound. To reset: disconnect the
ballast from power and reconnect or replace the lamp. The ballast must remain disconnected from power for (2) minutes to
reset. After 2 minutes, restore input power. Ballast should resume proper operation.
The equipment that this ballast is used with requires connection to a known good ground. It is the User's
responsibility to ensure that their equipment is properly grounded in compliance with the National Electrical Code and any
applicable local codes. Equipment wiring and hook up should be performed by a qualified, licensed electrician. Failure to comply
with this requirement could result in serious injury or death.
Germicidal Ultraviolet Lamps, visit AtlanticUltraviolet.com or Ultraviolet.com.
®
Table 3 – Troubleshooting
Possible Cause
No electrical power
Cracked or broken quartz sleeve
Quartz sleeve sealing O-Ring(s)
worn, damaged
Poor, or loose, connections or fittings
Quartz sleeve fouled
®
STER-L-RAY
Germicidal Lamp
output depreciating
STER-L-RAY
®
Germicidal Lamp
not functioning
Low input voltage
Change in water quality
Corrective Action
Verify that the purifier is connected to a live power source.
Shut down purifier, drain, and replace quartz sleeve. See "Quartz Sleeve
Installation, Cleaning, or Replacement" or "Replacement of Broken
Quartz Sleeve" in the "Maintenance" section.
Shut down purifier, drain, and remove static gland nut, replace sealing
O-Ring. See "Quartz Sleeve Installation, Cleaning, or Replacement"
in the "Maintenance" section.
Tighten suspect connection or fitting; or shut down purifier, drain,
and remove fitting or connection. Clean threads; reapply thread
sealing tape and reinstall.
Clean quartz sleeve, see "Quartz Sleeve Installation, Cleaning, or
Replacement" in the "Maintenance" Section.
Replace lamp, as it nears its end of life (EOL). See "Lamp Installation
or Replacement" in the "Maintenance" section.
Replace lamp. See "Lamp Installation or Replacement" in the
"Maintenance" section.
Verify input voltage to purifier.
Have water tested to confirm that it does not exceed maximum
recommended concentration levels for use with this purifier.
13