CONTROL PANEL

ON/OFF
ON/OFF
Press and release to turn unit on or off.

DISPLAY MENU

Press to select next item in menu. Menu item
will show in display.
MENU
Press to toggle or select values in menu
SELECTION /
displayed.
UP KEY
PURGE PUMP
Press and release to start purge. Display will
count down seconds remaining until purge is
complete.
your dehumidifier away from obstructions, and keep it
away from anything that could block airflow into and out
of the unit. For more information about creating an
optimum drying environment, contact your local
distributor.
Set up drain hose
Unwrap the entire hose and place the unattached end in
a sink, drain, bucket or outdoors – anywhere that water
can drain out safely. If you use a bucket or other
container for water collection, check it regularly to
prevent overflows. Verify hose fitting is attached to short
hose exiting the unit.
NOTICE: Uncoil and straighten the entire drain hose. Do
not leave any part of the hose coiled and do not place
the end of the hose higher than 6 m above the bottom of
the unit. Also check for kinks or other obstructions that
might restrict the flow of water. Obstructions may cause
a water backup and result in overflows.
Plug in electrical cord
The unit should be plugged into a 230V/50Hz or
110V/50Hz outlet depending on the model.
Startup display and normal display modes
When unit is first plugged in to AC power, the control
panel display will briefly cycle through a series of
readouts. This is part of the unit's self-diagnosis
procedure and no user intervention is required.
07-02282A F571-230V & F571-110V
PURGE PUMP
DISPLAY
MENU
SELECTION /
MENU
UP KEY
Fig. A: Parts Identification
Carry handles
Remove/Insert
air filter here.
Air inlet
Cord and
hose storage
compartment.
Turn the unit on
The control panel has a display and a touchpad with four
keys. Press the
ON/OFF to turn the unit on. The unit
will now go through a compressor delay countdown (up
to sixty seconds in duration) and an automatic
diagnostics process.
Once the compressor delay countdown and self-
diagnostics are complete, the display will switch to
normal display mode.
UNIT ON 00 HRS
INLET 00°C / INLET 00%
The first line of the display shows the total number of
hours the unit has been in operation. This value may be
reset to zero to track job hours (see "Job Hours Reset"
below). The second line of the display alternates
between inlet temperature and inlet humidity.
User Settings Menu
A number of display settings may be changed by the
user. System information can also be displayed. These
items are accessed by pressing
Each press of the key will display the next parameter.
When you reach the parameter you wish to adjust, press
MENU SELECTION to increase the value. Press
DISPLAY MENU again to accept the setting and re-start
the display cycle.
Note that only menu items followed by a greater-than
symbol ( > ) may be adjusted.
2
Air outlet
(both sides)
Control
panel
Air outlet
(both sides)
DISPLAY MENU.