The fuse is contained in a small plastic tray at the bottom of the power connector.
1.
Remove the power connector from the back of the Sanidyne
by inserting the blade in one of the horizontal slots and gently twisting the handle to bring the tray forward.
2. A spare fuse is accessible, clipped in front of the active fuse.
Step 1 – Insert
Screwdriver & Bring
Tray Forward
TROUBLESHOOTING
Always disconnect power to the fixture before performing any service or maintenance.
IN ORDER TO PERFORM THIS TASK, WEAR PERSONAL PROTECTION EQUIPMENT; GLOVES,
LONG SLEEVE SHIRT WITH NO GAPS BETWEEN CUFFS AND GLOVES, AND AN ULTRAVIOLET
BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN.
IMPORTANT: This fixture is to be serviced ONLY by qualified and factory authorized personnel.
Problem
Sanidyne
Prime
®
Remote not
operating
Lamp
STER-L-RAY
®
not operating
Sanidyne
Prime
®
Remote fails to
shut off
Table 1 – Troubleshooting
Possible Cause
Power disconnected
Fuse not operating
STER-L-RAY
®
Germicidal lamp faulty
Germicidal
STER-L-RAY
®
lamp not properly seated
Loose Connection
Surelite
™
Ballast not operating Disconnect the fixture from utility power; then replace ballast.
Microprocessor
assembly faulty
Prime Remote. A screwdriver can be used to access the fuse
®
Step 2 – Open Tray
(Spare Fuse is Clipped in
Front of the Active Fuse)
Corrective Action
Check connections.
Remove power connector to check and
replace fuse if necessary. (See Page 14)
Swap suspect lamp, with lamp known to be good.
If suspect lamp does not operate, replace lamp.
Check lamp socket and re-install lamp if necessary.
Inspect for loose or disconnected wires.
Wearing protective clothing and face shield, enter area, and
disconnect power to unit. Call factory for technical service.
15