TROUBLESHOOTING

Always disconnect power to the fixture before performing any service or maintenance.
IN ORDER TO PERFORM THIS TASK, WEAR PERSONAL PROTECTION EQUIPMENT; GLOVES,
LONG SLEEVE SHIRT WITH NO GAPS BETWEEN CUFFS AND GLOVES, AND AN ULTRAVIOLET
BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN.
IMPORTANT: This fixture is to be serviced ONLY by qualified and factory authorized personnel.
Problem
Possible Cause
Power disconnected
Sanidyne
Plus
®
not operating
Fuse not operating
STER-L-RAY
Germicidal lamp faulty
STER-L-RAY
STER-L-RAY
Lamp
®
lamp not properly seated
not operating
Loose Connection
Surelite
Sanidyne
Plus
Microprocessor
®
fails to shut off
assembly faulty

TECHNICAL SPECIFICATIONS

Model:
Volts:
Amps:
Hertz:
Maximum Treatment Time:
Weight:
Length: (Inches)
Dimensions:
Width: (Inches)
Height: (Inches)
Lamp Model:
Number of Lamps:
Lamp Data:
Power Consumption:  (Watts per Lamp)
Ultraviolet Output:  (Watts per Lamp)
Average Effective Life: (Hours)
Wattage is lamp watts only and does not include ballast loss.
 Ultraviolet output at 254nm at 100 hours and 80 °F (approximate).
All specifications, dimensional data, etc are approximate and subject to change without notice.
Table 1 – Troubleshooting
Corrective Action
Check connections.
Remove power connector to check and
replace fuse if necessary.
Swap suspect lamp, with lamp known to be good.
®
If suspect lamp does not operate, replace lamp.
Germicidal
®
Check lamp socket and re-install lamp if necessary.
Inspect for loose or disconnected wires.
Ballast not operating Disconnect the fixture from utility power; then replace ballast.
Wearing protective clothing and face shield, enter area, and
disconnect power to unit. Call factory for technical service.
Table 2 – Technical Specifications
40-5087C1
40-5087C2
120v
230v
10 A
5 A
50/60Hz
24 Hours
76 Lbs.
21-3/4"
20"
68-1/2"
05-0893
8
120W
35W
13,000
15