Troubleshooting

Problem
The power tool does not start.
The power tool switch trips out.
The flexible shaft is overheating.
The power tool vibrates too much.
The vibrating poker does not does not vibrate
but the power tool starts.
© 2015 Construction Tools PC AB | No. 9800 1191 01 | 2015-03-04
Original instructions
Cause
The plug is not connected.
Start switch is in off position.
The carbon brushes are worn out.
No power in the power socket.
The internal vibrator is overloaded (when
operating in concrete or rebar).
Air inlet or outlet is clogged and the power
tool is not cooled.
The electric motor fan is broken and the
power tool is not cooled.
Too much friction in the flexible shaft.
Too much grease on the flexible shaft.
Too much torque inside the the vibrating
poker (the bearings get worn out).
Too much friction in the flexible shaft.
The bearings of the power tool are worn out.
Too much friction in the flexible shaft.
The bearings in the in the vibrating poker are
broken.
The flexible shaft is broken.
Safety and operating instructions
Solution
Connect the electrical plug into a power
socket.
Turn the switch on.
Change the carbon brushes.
Replace or repair the power socket.
Raise the the vibrator poker from the
concrete and immerse it again.
Remove anything that may obstruct the air
inlet or outlet.
Replace the fan at an authorised workshop.
Grease the flexible shaft in the hose.
Respect the quantity of 20 grams per meter
of flexible shaft.
Replace the bearings in the vibrating poker.
Grease the flexible shaft in the hose.
Replace the bearings in the power tool at an
authorised workshop.
Grease the flexible shaft in the hose.
Replace the bearings in the in the vibrating
poker.
Replace the flexible shaft.