Maintenance

General
It is recommended to regularly submit the tool to maintenance, or as soon as the hammer mechanism
gets weak, or when the carbon brushes switch off. When carrying out maintenance all parts of the
maintenance set must be exchanged. Use the respective maintenance set provided for each machine.
Cleaning
Clean all parts – with the exception of the electrical parts – with cold cleaning agent. Caution! No
cleaning agent should penetrate into the bearing. Clean the electrical parts with a dry brush.
Check for wear
Check the disassembled parts for wear (visual inspection) and replace worn parts.
Electrical tests
Before reassembling, perform an electrical test on all relevant parts (see chapter Electrical and
Mechanical Test Instructions).
Lubrication
Each time maintenance is performed, the machine is to be lubricates as stated in the lubrication plan.
After the machine is fully disassembled, completely remove the old grease and replace with new
grease. The grease must be applied to the machine as indicated in the lubrication plan.
Legend
A Cover generously
B Filling
Torques
Screws M 4
Screws M 5
Repair Instructions No. 162.11/95