Characteristic
Pressure at point of connection
Max. quantity of particles in suspension
Max. diameter of particles
Dew point
Max. quantity of oil in suspension
Whenever not utilizing natural base oils compatible with existing health regulations, it is necessary to
adjust the mixer pressure so as to avoid the formation and dispersion of oil mist into the environment.
The mixing pressure is indicatively between 1 and 2.5 Bar.

8. CONTRAINDICATIONS

The VIP4Tools panel does not have any particular contraindications except for the following points:
The operator coming into contact with fluid due to breakage/opening of supply tubing.
The operator must be furnished with suitable personal protection clothing/equipment (part VIII –
626 [Safety at Work legislation]).
Abnormal posture.
Take note of the indications shown in paragraph 10.2.
Contact with oil during filling/maintenance.
The operator must be furnished with suitable personal protection clothing/equipment (part VIII –
626 [Safety at Work legislation]).
Use of unsuitable lubricants.
Main inadmissible fluids.
Lubricants with abrasive additives
Lubricants with silicon based additives
Petrol – solvents – flammable liquids
Corrosive products
Water
Food substances

9. INSTALLATION

9.1 UNPACKING
Once a suitable location has been identified for the installation, open the package and remove
the equipment. Check that the VIP4Tools has not sustained damage during transport and
storage.
The packaging material does not require any special disposal precautions, not being in any
way dangerous or polluting.
9.2 MOUNTING THE VIP4Tools PANEL
Provide adequate space for the installation, leaving a minimum room of 100 mm around the
panel. Mount the VIP4Tools panel at shoulder height to avoid unnatural posture or the
possibility of sustaining impacts. Do not install the VIP4Tools in particularly aggressive or
explosive/flammable environments or on components subject to vibration.
Only use the supplied mounting bracket with N° 2 holes for Ø6 mm bolts.
AIR CHARACTERISTICS
Fluid
Requirement
Min. 6 Bar
15 mg/Nmc
0.05
2° C
5 mg/Nmc
Danger
High wear rate of contacted parts
Seizure of the pump
Fire – explosion – damage to seals
Corrosion of the pump– injury to persons
Oxidation of the pump
Contamination of the substances themselves