6. UNPACKING AND INSTALLING THE PUMP
6.1 UNPACKING
Once a suitable location has been identified for the installation, open the package and remove the equipment. Check that the
VIP4Air has not sustained damage during transport and storage.
The packaging material does not require any special disposal precautions, not being in any way dangerous or.
6.2 MOUNTING THE VIP4Air PANEL
Provide adequate space for the installation, leaving a minimum room of 100 mm around the panel. Mount the VIP4Air panel at
shoulder height to avoid unnatural posture or the possibility of obscuring the control panel or of sustaining impacts. Do not
install the VIP4Air in particularly aggressive or explosive/flammable environments or on components subject to vibration.
Only use the supplied mounting bracket with N° 2 holes for Ø6 mm bolts.
6.3 MOUNTING THE MINI-PUMPS ON THE MIXER BASES (for replacement or augmenting)
The mini-pumps are mounted on the mixer bases utilizing two securing screws.
Particular attention should be paid to the correct positioning of the o-rings between the mini-pump and the mixer base (see
diagram below).
6.4 MOUNTING THE DOSER ASSEMBLY ON THE PUMP (for replacement or augmenting)
To install a new mixer unit proceed as follows:
1. Disconnect the electrical power supply from the VIP4Air panel and empty the tank of oil.
2. Disconnect the air supply from the solenoid valve and remove the three securing screws.
3. Unscrew the screws which secure the blanking plate.
4. Connect the new base, inserting the electrical bridge, paying particular attention to the alignment. Secure the unit using the
two screws supplied for the purpose.
5. Reposition the blanking plate and the relative solenoid valve.
Electrical
bridge
Securing screws
Mini-pump
Seals
Mixer base
Grub screw
Seals
Base Assembly
Securing screws