DRYDEN AQUA DA-GEN 1000 Посібник з експлуатації - Сторінка 3
Переглянути онлайн або завантажити pdf Посібник з експлуатації для Системи фільтрації води DRYDEN AQUA DA-GEN 1000. DRYDEN AQUA DA-GEN 1000 3 сторінки.
4.1
4.4
4.5 It corresponds to the behavior of the system after AL3 activation:
Ignore – AL3 is not shown in the display.
Inform – After the selected interval, the AL3 alarm is displayed
on the display.
Force stop – After the selected interval, the AL3 alarm is displayed
on the display and the dosing pump stops. To reset the alarm and the dosing
pump, press
.
5.1
6.1
7.1
8.1
4. DOSING PUMPS
4.2
4.5
5. EXTRA SETTINGS
5.2 Gas (0) - The FL1 alarm is only activated by cell's gas sensor (external flow switch annulled).
5.2
Siempre ON (1) - The FL1 alarm is never activated (invalidates cell's gas sensor and external flow switch);
Paddle (2) - The FL1 alarm is activated by external flow switch (gas sensor annulled).
Paddle or gas (3) - When both cell's gas sensor and external flow switch are connected, and either of them detects
lack of flow, The FL1 alarm is activated. To connect the external flow switch use the FL1 terminal (see Electronic Box
Electrical Connections).
Paddle + Gas (4) - When both cell's gas sensor and external flow switch are connected, and both of them detects
lack of flow, The FL1 alarm is activated. To connect the external flow switch use the FL1 terminal (see Electronic Box
Electrical Connections).
Relay control through flow detection - Manage the FL1 alarm deactivation in case of lack of flow. Recommended
option for floculant dosification or similar.
6. COUNTERS
6.2
6.3
7. CONNECTION
7.2
7.2 Comunicación (Conexión): Used for the configuration of more than 2 user interfaces.
For normal operation of the system, keep the value to 1 for this parameter.
8. WEB IP
8.2
8.2 Server control and connection port in case there is WIFI Module connected to the system.
For the proper functioning of the system, do not change the default values unless you receive a notice from your provider.
4.3 Dosing pumps associated to pH, redoX and/or Chlorine allows the
4.3
configuration of the following parameters:
Delay – Delay time between detection of incorrect value and the start of
dosing.
Interval – Time interval until the dosing pump AL3 alarm is activated. At
zero (0) the alarm is never activated. This alarm indicates that the dosing
pump has been activated, but has not reached the desired level. AL3 is
shown on the main screen; in order to delete this message and reactivate
the dosification, press
4.6
4.7 You can associate the level sensor (TANK) to the pH or chlorine (rX). This menu
corresponds to the behavior of the system after the TANK signal activation (acid
deposit level TANK).
Ignore – TANK is not shown in the display
Inform – When the sensor detects that the level is low, the TANK alarm is displayed.
Force stop – When the sensor detects that the level is low, the TANK alarm is
displayed and the associated dosing pump stops.
6.2 Reset counters: There are two levels of working hours counters which log the
working hours of the components and devices.
In this service menu the installer can reset the working hour counters on the first
level (for example when a new cell is installed).
The second level of the working hour counters can only be accessed by the factory.
.
4.7