Dryfast DAF1600 Інструкція з експлуатації - Сторінка 4
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Вентилятор Dryfast DAF1600. Dryfast DAF1600 19 сторінок. Axial fan
EN
Storage
•
Store the device in a clean, dry indoor area to ensure a long
service life .
•
Never store the appliance dirty
Specifications
Model
Air flow
Air pressure max
Hose connection
Air flow
Power supply
Power consumption
Recommended fuse
Mobility
Dimensions L x W x H
Weight
IP class
Noise level
Faults
Please note that electrical faults should only be rectified by qualified personnel only .
Faults
The fan does not run
The fan only runs for a short time and then
then switches off again
The position of the fan changes during
operation
Air output is too low
The fan makes an abrasive noise
The device vibrates
4
DAF1600
1360
m³/hour
155 Pa
2 x ø 200 mm
free blowing
230 V / 50 Hz
0,25 kW
10 A
portable
365 x 265 x 390 mm
Net: 7 .5 kg
Gross: 8 kg
44
max . 72 dB(A) @ 1 m
Rectifying faults
•
Check that the appliance is switched on .
•
Check the mains connection .
•
Check the mains cable and plug for damage .
•
Check the building installation fuse
Check whether the protective grille at the air intake is blocked . Remove any
foreign objects . The motor bearing may be damaged . Contact
contact the dealer where you purchased the fan .
Check for missing, damaged of dirty rubber feet . Clean if necessary
Check whether the protective grille is clogged and clean it if necessary
•
The fan blades may be dirty or there are foreign objects within the rotating range
of the fan . Clean the fan blades or the fan unit according to the maintenance
chapter .
•
Fan blades possibly damaged . Contact the dealer from whom you the fan was
purchased
•
Check the fan set-up surface . Place the device on a solid and flat surface .
•
Check the screws, especially the space between fan unit and tube frame . Tighten
the screws if necessary .
•
Check the fan blades for dirt and clean them,if necessary .
•
Any imbalance at the fan blades . Contact the dealer where you purchased the
fan .
DAF3000
3000 m³/hour
295 Pa
2 x ø 300 mm
free blowing
230 V / 50 Hz (3,8 A)
0,65 kW
10 A
portable
520 x 400 x 500 mm
Net: 13 kg
Gross: 14 kg
44
max . 65 dB(A) @ 1 m