Replace a pleated filter
(Replace the pleated filter when the "replace indicator" on the
main unit display turns on or blinks.)
turn on
1. Remove the front panel.
2. Remove the plasma ionizer.
• Holding the handle, lift towards yourself and remove from the top
2 hooks.
Plasma ionizer
3. Replace a pleated filter with new one.
1) Remove a used pleated filter.
• Remove a pleated filter from the tape at bottom of the
deodorization catalytic unit and then unhook the hooks
(3 locations on top and 2 locations on bottom).
Pleated Filter
Securing tape
2) Take out a new pleated filter (1 sheet) and then attach it to the
deodorization catalytic unit.
• Hook on top and bottom hooks, insert into left and right hooks
and then secure with the tape.
3) Place the pleated filter holes on the 3 upper tabs of the
deodorizing catalyst unit.
The side with the three holes goes up.
The white side should be facing you.
4) Hook the holes of the pleated
filter on the bottom hooks.
(2 locations)
(page 9.)
Hooks
(one left and one right)
Top hooks
(3 locations)
Deodorizing
catalyst unit
Bottom hooks
(2 locations)
5) Insert the pleated filter into the
left and right hooks.
6) Secure the pleated filter with the
tape.
4. Restore the plasma ionizer and the front panel.
5. Insert the power plug.
6. Press the reset switch on the main unit display.
Press the reset switch
with a sharp material
such as a tooth pick to
turn off the replacement
sign. (It will beep.)
NOTE
Replace a pleated filter
•
Contact your dealer for replacement pleated filter.
•
It is not necessary to replace a pleated filter until the replacement
sign turns on or blinks. When the replacement sign turns on, replace
a filter even though it is not dirty.
*
Apparent dirt is not proportional to filter performance.
•
The replacement timing of the pleated filter differs depending on
usage and installed place.
The replacement sign turns on after a year of everyday use in a
home where 10 cigarettes are smoked per day.
(The replacement timing will be shorten for use in a heavily air
polluted place.)
Remove the plasma ionizer
CAUTION
•
When cleaning be careful not to cut your hands on the ionizing line.
(Wearing rubber gloves is safer.)
1. Remove the front panel.
• Lay your finger to the
dent at bottom of the
main unit, hold bottom
part of the panel and
then pull it up.
2. Remove the pre-filter.
(page 9.)
(page 6.)
Front
panel
10
English /