Drytac HOT PRESS HGP560 Посібник користувача - Сторінка 16

Переглянути онлайн або завантажити pdf Посібник користувача для Електроінструмент Drytac HOT PRESS HGP560. Drytac HOT PRESS HGP560 19 сторінок. Heated glass top vacuum press
Також для Drytac HOT PRESS HGP560: Посібник оператора (19 сторінок)

Drytac HOT PRESS HGP560 Посібник користувача
HOT PRESS USERS MANUAL
Troubleshooting
E
T
LECTRICAL
ROUBLESHOOTING
1. Press shows no readings on temperature or timer controls
• Check the two circuit breakers on the rear panel of the unit. The
levers should both be pointing to the right (as seen from the back).
Some models have circuit breakers with a color code – green indicates
off, and red indicates the on position.
• Check power source – verify that the power cord is fi rmly connected,
and that the power outlet is live. If it is not, check the circuit breaker at
the building's electrical distribution panel.
• Unplug the power cord and check the fuses on the left side of the
unit.
2. Press starts up normally, then overheats and shuts off, or the
temperature controller displays an error code such as "PFA" or
"LOR".
• There is a problem with the temperature controller or temperature
sensor. Contact Drytac for assistance with repairs.
3. Vacuum pump does not operate in either automatic or manual
mode.
• Electrical cable from pump to rear panel of vacuum press is
disconnected.
• Pump fuse (on left side panel has blown). Unplug the power cord
and check the fuse.
• Vacuum pump has failed.
16