Absolute HP- 120 Посібник - Сторінка 9
Переглянути онлайн або завантажити pdf Посібник для Водяний насос Absolute HP- 120. Absolute HP- 120 9 сторінок. Air pump
HP- 100 / 120
S
T
E
P
S
T
E
P
FITTING THE ELECTROMAGNET
4
4
Mount new the electromagnets in the unit.
Tighten up nuts with nut driver.
S
T
E
P
S
T
E
P
5
5
Install the SP switch to the frame with the screws.
●Be careful of the direction of switch lever. (Refer to the
pictures)
S
T
E
P
S
T
E
P
6
6
Insert the wire into the silicon tube, and tie up in a
bundle.
Strip the coating off each wire.
(5-7mm from the end)
Connect the wires to the terminals.
Solder the wires to the terminals.
The wire requires a soldered connection.
S
T
E
P
S
T
E
P
7
7
This completes the electromagnet replacement
procedure.
REPLACING THE ELECTROMAGNET
9