DSC PC510 Посібник з монтажу - Сторінка 8
Переглянути онлайн або завантажити pdf Посібник з монтажу для Система безпеки DSC PC510. DSC PC510 20 сторінок.
Disarming
Enter the premises through the designated Entry-Exit door. The keypad will sound a tone to indicate that the
system must be disarmed. Go to the keypad and enter an Access Code. If an error is made entering the code,
press the [#] Key and enter the code again. The "Armed" light will be shut OFF and the sounder will be silenced.
An Access Code must be entered before the Entry Delay expires or an alarm will sound. To change the Entry
Delay, refer to Programming Section [2].
If an alarm occurred while the system was armed, the "System" light and the zone lights of the zones that went
into alarm will FLASH for two minutes. Press the [#] Key to cancel the flashing display and to return the system
to the "Ready" mode. Refer to [
∗
[
]+[0]: Quick-Arm
The Quick-Arm feature allows a user to enter [
someone to arm the system without that person having to be provided with an Access Code. When [
entered, the Exit Delay will begin and the user may exit the premises through the Entry/Exit door. At the end
of the Exit Delay, the system will be fully armed.
∗
[
]+[1]+[Access Code]: Zone Bypassing
A bypassed zone will not cause an alarm. Use zone bypassing when access is needed to part of a protected
area when the system is armed, or if damage to sensors or wiring cannot be repaired immediately. The system
may be armed with one or more zones bypassed even if the zones are open.
With the system disarmed, enter [
bypassed zones will come ON. Ensure that any zone displayed as being bypassed is intentionally bypassed.
Zone bypasses are automatically cancelled when the system is disarmed.
To Bypass Zones:
∗
Enter [
][1][Access Code]; the "System" light will FLASH.
Enter the number of the zone to be bypassed; the corresponding zone light will come ON to indicate that the
zone is bypassed. To remove a bypass, enter the zone number and its zone light will be shut OFF. When all
desired zones are bypassed, press the [#] Key to return to "Ready".
∗
[
]+[2]: Display Trouble Conditions
The PC510 monitors two possible trouble conditions. If an AC Failure occurs, the "System" light will come
ON. If both the AC Failure and Battery Trouble are present, the "System" light will come ON and the keypad
sounder will sound two short beeps every 10 seconds. To silence the sounder, press the [#] Key; the sounder
will be silenced but the "System" light will remain ON until the AC Failure trouble is cleared.
To display trouble conditions, enter [
light comes ON, then that trouble condition is present:
Zone Light
1
Battery Trouble. If the battery voltage is low, a battery trouble will be displayed. Note that the
Battery Trouble will only be indicated if AC power is off.
2
AC Failure. If AC power is removed from the system, an AC trouble will be displayed.
∗
[
]+[3]: Display Alarm Memory
Alarms caused during the previous armed period are stored in memory. To display the zones that went into
∗
alarm, enter [
][3]. The "System" light will FLASH and the alarms will be displayed on the flashing zone lights.
The Alarm Memory will be cleared when the system is armed.
∗
[
]+[4]: Bell Test
∗
Entering [
][4] will sound the siren and turn ON all the keypad lights for 2 seconds.
6
∗
][3]: Alarm Memory Display.
∗
][0] to arm the system. This command is designed to allow
∗
][1][Access Code] to display the bypassed zones; the zone lights of
∗
][2]. Trouble conditions are represented with the zone lights; if a zone
firealarmresources.com
∗
][0] is