5. Main configuration operations
The sliding part and the push-button are factory-programmed for the "Silent alarm" command.
Pendant programming makes it possible to customise the command sent by the sliding part and/or push-button,
depending on the user's needs:
1. Choose whether you want the sliding part or the push-button to trigger the alarm.
2. Choose a command n° from the table below to correspond to the chosen trigger (sliding part or push-
button).
Command description
Alarm
Silent alarm (factory)
Local call
3. Perform programming according to the sequence described on the next page.
ADVICE: before doing anything, study the programming sequence and example on the next page. Check
the programming LED making sure to press the push-button for the required amount of time.
IMPORTANT: when the LED flashes red 3 times in a row during or after programming, this indicates that there has
been a programming error. When this happens, perform programming again from the start.
System response in user mode depending on the command sent
Command
n°
22
sounding + control panel relay triggering:
90 sec.
24
control panel relay triggering: 90 sec.
28
"beep, beep, beep, beep, Urgent call...": 3 min.
Control panel
9
Siren
Dialler
sounding:
transmission
90 sec.
no response
transmission
no response
no response