DSC PC1000 Інструкція з експлуатації
DOOR CHIME FEATURE
The door chime feature is used, while the panel is disarmed, to provide a tone from
the keypad each time a door or window is opened or closed. The doors and windows
which will provide this indication are programmed by your installer.
Enter[*] [5], [Master Code],
[OJ
to turn the door chime feature ON and OFF. When
the command is entered, the keypad will beep 3 times if the feature is being enabled
and will sound one beep if the feature is being disabled.
SPECIAL FUNCTION COMMAND
The PC1000 can be programmed at the time of installation to operate other devices
such as electric door strikes, door openers, electric lights, cameras, etc. by pressing
[*] then [7] on the keypad. Your installer will instruct you on the use of this command.
AT-HOME ARMING COMMAND
Entering[*], [9] before the 4 digit arming code arms the panel with no entry delay
on the entry zones, and bypasses the interior zones that have been programmed as
"home-away" zones. This command is used to arm the system if someone is
remaining on the premises.
KEYPAD ZONES
There are three zones which can be activated from the keypad. A fire alarm is
activated by pressing the [1] and [3] keys at the same time. The fire alarm sounds
the bell/siren in a pulsed mode. A transmission will be sent to the monitoring station
ONLY if it has been programmed to do so by the installer.
The PC1000 can be programmed at the time of installation to send a transmission to
the monitoring station by simultaneously pressing keys [4] and [6]. The installer will
provide instructions on its use when required.
The Police (or Panic) alarm is activated by pressing the [*land[#] keys at the same
time. The panic alarm can be programmed to be audible or silent. There is no
annunciation from the keypad. A transmission will be sent to the monitoring station
ONLY if it has been programmed to do so by the installer.
AUTO-TEST TRANSMISSION
The PC 1000 can be programmed at the time of installation to send a test code to the
monitoring station at regular intervals. The frequency and time of the test transmission
is set by the monitoring station and should not be changed without their knowledge.
8
FIRE LOOP OPERATION
ARMED MODE ("Armed" light ON)
1. On alarm the signal will pulse.
2. Enter access code to silence the signal and also disarm the panel.
3. Press [*l then [7] to reset the smoke detector(s) if the panel has been
programmed to do so; "System" and "Ready" lights will come ON steadily.
DISARMED MODE ("Ready" light ON)
1. On alarm the signal will pulse; zone 4 and "System" lights ON steadily
2. Enter access code to silence signal.
3. Press [*] then [7] to reset the smoke detector(s) if the panel has been
programmed to do so; "System" and "Ready" lights will come ON steadily.
FIRE LOOP TROUBLE
1. Open circuit on the fire loop (zone 4 ); "System" light ON steadily and keypad
sounder beeps.
2. Press [#] to silence the trouble.
3. Press [*]then [2] to view the source of trouble; "System" and zone 3 lights flash
to indicate a trouble on the fire loop (zone 4).
4. Press[#] to exit view-trouble mode; "Ready" and "System" lights will come ON
steadily.
5. When the trouble condition is repaired, the "System" lights will go OFF leaving
only the "Ready" light ON.
TESTING
IT IS RECOMMENDED THAT THE SYSTEM BE TESTED ON A WEEKLY BASIS
NOTE: Perform system tests in the off-peak hours, such as early morning or late
evening.
1. Inform the monitoring station that you are testing your system.
2. Disarm the system ("Ready" light should be ON).
3. Perform a battery/bell test by pressing[*] then [4]. The alarm will sound for
about 2 seconds. If a trouble occurs after the test, press[*], [2] to view the
trouble condition.
4. Activate each sensor in turn (e.g. open a door or window). Observe the zone
light come ON as each sensor is activated. The zone light will go OFF as each
sensor is restored to normal (door or window is closed).
5. Press the [1] and [3] keys at the same time. The signal will sound in a pulsed
mode. Arm then disarm the panel to silence the signal.
Continued... ►