Absolute Measurement ACDF-3 Інструкція з експлуатації - Сторінка 5

Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Діапазони Absolute Measurement ACDF-3. Absolute Measurement ACDF-3 8 сторінок.

Transducer Instruction Manual
Range:
Advance
Type:
ACDF – 3
Revision:
V1.0
2.6

Transducer and Sensing Roller Installation

The transducer should be mounted so that the Measurement Direction is in the direction of the resultant
tension force. The cable connector is at right angles to the Measurement Direction.
One end of the sensing roller should be held in the bearing of one transducer, as at 'A' above; the other
end of the roller must be free to move or "float" axially in the other transducer bearing, as at 'B' above.
This float must allow the overall distance between transducers to be reduced by at least 8mm to permit
the transducers and roller assembly to fit inside the machine frames for installation. The transducers may
also be fitted on the outside faces of the frames to allow full use of the machine width. Alternatively
provision must be made to fit the complete transducers and roller as an assembly into the machine
axially. The bearing is retained in the transducer by circlips. It is recommended that only the plain side
plate "A" of the transducer be removed for bearing access, see the Transducer Dimension drawing for
details.
2.7

Temperature Compensation and Shaft Expansion

The transducer is supplied with a temperature compensation network which is in series with Pin D, the
output signal lead. The compensation circuit will operate correctly only when used with a tension indicator
or controller supplied by CMC Controls. The transducer can accommodate sensing roller shaft expansion
due to normal temperature changes. The transducer, sensing roller and machine structure should all
therefore be at normal room temperature during installation
_____________________________________________________________________________________________________________________
Absolute Measurement Ltd. (T/A CMC Controls)
t: (0) 1732 763278
| e:
Unit 19
| Silver Birches Business Park | Aston Road | Bromsgrove | B60 3EU
| w: absolutemeasurement.co.uk
4