DESCrIPTION
The accumulation tanks ATTACK Hr, HrS are made from the quality steel
and serve for accumulation of the heating water as well as for preparation of
the D.H.W. by an internal enameled exchanger. The ATTACK HrS model is
accessorized with an extra exchanger to be connected to the solar system.
Tanks of this type have a built-in magnesium anode in the D.H.W. tank
to increase resistance against corrosion. The manual deaeration valve is in-
stalled in the upper part.
ATTACK Hr: 9× socket G 1 ½", 6× socket G ½"
ATTACK HrS: 9× socket G 1 ½", 6× socket G ½", 2× socket G 1" – solar circuit
KEy fOr THE ACCUMULATION TANKS
1 – Flow connection – boiler . . . . . . . . . . . . . 1 ½"
2 – Freely disposable . . . . . . . . . . . . . . . . . . 1 ½"
3 – Electrical heating coil (EL) . . . . . . . . . . . . 1 ½"
4 – Freely disposable . . . . . . . . . . . . . . . . . . 1 ½"
5 – Return connection – heating circuit . . . . . . 1 ½"
6 – Flow connection – heating circuit (radiators) 1 ½"
7 – Flow connection – heating circuit (floor) . . . 1 ½"
8 – Return connection – gas, oil and pellet boiler 1 ½"
9 – Return connection – wood boiler . . . . . . . 1 ½"
TECHNICAL PArAMETErS
HR600K
1 515 1 123 794 650 684 245
HR800K
1 545 1 135 846 735 725 315
HR1000K
1 735 1 255 1 036 735 775 295
HR1250K
1 655 1 175 988 880 695 285
HR1500K
1 755 1 345 1 072 920 820 375
HR2000K
1 955 1 408 1 314 1 000 862 315
HRS600K
1 515 1 123 794 650 684 245 245 725 700 900 1 754 1 854 1 841 95
HRS800K
1 545 1 135 846 735 725 315 315 725 790 990 1 806 1 906 1 898 95 105
HRS1000K 1 735 1 255 1 036 735 775 295 295 860 790 990 1 996 2 096 2 081 95 121
HRS1250K 1 655 1 175 988 880 695 285 285 850 950 1 150 1 948 2 048 2 064 95 142
HRS1500K 1 755 1 345 1 072 920 820 375 375 895 1 000 1 200 2 032 2 132 2 160 95 161
HRS2000K 1 955 1 408 1 314 1 000 862 315 315 843 1 100 1 300 2 274 2 374 2 390 95 188
10 – Sensor of solar system or heating . . . . . . . ½"
AS – Flow connection of solar system . . . . . . . . 1"
RS – Return connection of solar system . . . . . . . 1"
D1 – Diameter without insulation
D2 – Diameter with insulation
CN – Pump of the circulation tank . . . . . . . . . . ¾"
AF – Cold drinking water . . . . . . . . . . . . . . . . ¾"
AC – Hot drinking water . . . . . . . . . . . . . . . . . ¾"
MA – Magnesium anode . . . . . . . . . . . . . . . . . –
Tank
-
-
700 900 1 754 1 854 1 841 95
-
-
790 990 1 806 1 906 1 898 95 105
-
-
790 990 1 996 2 096 2 081 95 121
-
-
950 1 150 1 948 2 048 2 064 95 142
-
-
1 000 1 200 2 032 2 132 2 160 95 161
-
-
1 100 1 300 2 274 2 374 2 390 95 188
ACCUMULATION TANKS
Solar
Internal
exchanger
99
3
-
-
-
160 95
3
-
-
-
160 95
3
-
-
-
160 95
3
-
-
-
160 95
3
-
-
-
160 95
3
-
-
-
160 95
99
3
1,8 11,9 10 160 95
3
2,4 15,9 10 160 95
3
3 19,8 10 160 95
3
3 19,8 10 160 95
3
3,6 19,8 10 160 95
3
4,2 23,7 10 160 95
Tank
tank
6
445 157
6
553 157
6
731 172
6 1 079 172
6 1 260 265
6 1 800 296
6
445 157
6
553 157
6
731 172
6 1 079 172
6 1 260 265
6 1 800 296
7