3 – Configuration
Configuration of the CommandHub is done by accessing its internal web interface using any device with a web browser.
The web interface is available on any of three different IP addresses depending on which port the browser is accessing
the web interface through:
1)
The IP address of the Dante Ethernet port if using the Dante Network port.
2)
The IP address of the Command Ethernet port if using the Command Network port.
3)
A static IP of 192.168.0.1 through the command port.
*Note: The command port has an alias IP of 192.168.0.1 that is fixed and cannot be changed. Care should therefore be
taken to ensure there are no other devices on the control network that use this IP. This includes the IP address of
management interfaces on other hardware.
3.3 – Routing Interface Configuration
The Routing Interface configuration is separate from the proxy interface configuration as the routing and monitoring
commands are dealt with directly by the CommandHub itself and not passed through to other devices for processing. In
addition, it also uses a TCP/IP socket connection rather than UDP.
The TCP port is the port number the control device should connect a socket to when using the routing interface. This
port number must be different to the Control Proxy's UDP listen port.
© Attero Tech LLC 2015
3.1 – Port Configuration
The port configuration sets the network configuration for each of the
two Ethernet interfaces. Either port can be set to use a dynamic IP
address of a static one. If set to "Dynamic" but no DHCP server is
found, the interface will default to using a local-link address.
************************** IMPORTANT **************************
It is recommended that the control port be set to a static IP address.
Using a dynamic address could result in the IP address of the
CommandHub changing which, unless the control system has some
way to detect what the new IP address of the CommandHub is, will
result in the control system being unable to communicate with the
CommandHub or the devices on the Dante network.
*********************************************************************
3.2 – Control Proxy Configuration
The CommandHub can be used as a proxy to relay UDP commands for
configuration and monitoring of Attero devices from the control
network to devices on the Dante network.
The "Listen Port" is the port number used by the command interface
to listen for UDP command messages meant for Attero Tech devices
on the Dante network. This must have a different port number to the
routing and monitoring TCP port.
The "Response Port" is the port that any response from the Attero
Device will be sent back to on the device that sent the original
command.
Information on what commands each device support can be found in
the 3
Party Software API document available from the Log-In section
rd
of the Attero Tech website.
Page 7
CommandHub
User Manual
614-00019-01