AirTools Ulysses 8116 Посібник із швидкого старту - Сторінка 6
Переглянути онлайн або завантажити pdf Посібник із швидкого старту для Музичне обладнання AirTools Ulysses 8116. AirTools Ulysses 8116 10 сторінок. 16x analog output
Quick Start Guide
Ulysses 8116
16x Analog Output
Redundant Operation
Redundant Operation
The following tables describes the possible failure modes and how they are handled with and without a redundant hardware pair.
Failure Handling with Redundant Pair
Failure
Power Supply Failure
Fan Failure
DSP Failure (crash or hardware prob-
lem)
FPGA Failure
Watchdog timeout (software hang)
Running factory code (boot mode switch
activated, upgrading firmware or failed
firmware upgrade)
Problem with previous boot (crashed and
didn't power down normally last boot)
Failure Handling without Redundant Pair
Failure
Power Supply Failure
Fan Failure
DSP Failure (crash or hardware problem) Go offline
FPGA Failure
Watchdog timeout (software hang)
Running factory code (boot mode switch
activated, upgrading firmware or failed
firmware upgrade)
Problem with previous boot (crashed and
didn't power down normally last boot)
Action
Switch to secondary unit Failed unit's status light = flashing red and unit is offline *
Switch to secondary unit Failed unit's status light = blipping red and unit is inactive
Switch to secondary unit Failed unit's status light = flashing red and unit is offline *
Switch to secondary unit Failed unit's status light = flashing red and unit is offline *
Switch to secondary unit Failed unit's status light = flashing red and unit is offline *
Switch to secondary unit Failed unit's status light = blipping red and unit is inactive
Switch to secondary unit Failed unit's status light = blipping red and unit is inactive
* unit will light status light to indicate fatal failure as long as the nature of the failure allows it to do so
Action
Go offline
Indicate non-fatal error
Go offline
Go offline
Indicate non-fatal error
Indicate non-fatal error
* unit will light status light to indicate fatal failure as long as the nature of the failure allows it to do so
To download the latest version of Studio Matrix Designer, the Windows application
that controls all Studio Matrix hardware, go to: www.airtoolsaudio.com
Indications
Indications
Status light = flashing red and unit is offline *
Status light = solid red and unit is active
Status light = flashing red and unit is offline *
Status light = flashing red and unit is offline *
Status light = flashing red and unit is offline *
Status light = solid red and unit is active
Status light = solid red and unit is active
Symetrix
Engineered by
TM
6/9