ATX SignalOn N-M 32M0 Series Посібник з монтажу та експлуатації - Сторінка 8

Переглянути онлайн або завантажити pdf Посібник з монтажу та експлуатації для Блок управління ATX SignalOn N-M 32M0 Series. ATX SignalOn N-M 32M0 Series 20 сторінок. Rf passive modules

CHAPTER 1: GENERAL DESCRIPTION
1.2.

Diplex Filter Module

SignalOn diplex filter modules allow for passive band splitting of both forward, and reverse signals. Each module houses
three separate diplex filter circuits. All circuit connections are accessible on the rear of the module housing. Attenuator pads,
and test points similar to splitter/combiner modules are not available on this module.
1.3.
Condition & Monitor Module
The condition and monitor module allows a signal to be passed through two make-before-break pad sockets before being
monitored by a –20 dB directional coupler. This allows a technician the ability to use one pad socket for padding and one pad
socket for equalization. A simplified Condition and Monitor schematic is shown in Figure 2.
1-2
EQ
MON
-20 dB
Figure #2: Condition and Monitor Module Schematic
PAD
INPUT
OUTPUT
SignalOn
Series – RF Passive Modules - Installation & Operation Manual
®
ATX Confidential & Proprietary