5.4
Temporary Bypass
When the TH136 is in Auto or Frost Protection mode, you can bypass
the mode for two (2) hours. The TH136 will maintain the temperature
bypass for two (2) hours, then return to previous operating mode. Set
the temperature using these buttons
the bypassed mode will flash to indicate the bypass.
Pre-programmed Schedule
The TH136 programmable thermostat is pre-programmed with the
following schedule:
Time you wake
Time you leave
up and desired
and temperature
temperature
during your
absence
Programs 1 and 4 are repeated from Monday to Sunday.
Programs 2 and 3 are repeated from Monday to Friday.
Modify the Schedule
To modify the pre-programmed schedule, follow these steps:
Press the button associated with the program you wish to
modify.
Enter the program start time using the
Press the program button again.
Enter the desired temperature using the
Press
to exit.
NOTE:
After 60 seconds of inactivity, the thermostat will automati-
cally exit programming mode.
The TH136 thermostat is equipped with the Early Start function
(deactivated
by
default).
Programming.
Advanced Programming
You must hold the Auto button for 3 seconds to access the advanced
programming. Then, press Auto to select a menu.
Menus
Default
PPd MO
PPd TU
PPd WE
PPd TH
PPd FR
PPd SA
PPd SU
CPH
HLd
ES
OF (off)
PP
OF (off)
Press Auto until the desired menu is displayed.
To modify the default programming, use the
select from the available options.
Press
to exit.
NOTE:
Menus are detailed below.
8.1
Modify the Number of Programs per Day (PPd)
You can select the number of programs to be executed for each day
of the week. This means, you can run all 4 programs, only 2 (1st and
4th) or none (0).
NOTE:
When none (0) is selected, the TH136 will maintain the tem-
perature setpoint of the last program.
TH136
. The icon corresponding to
Time you return
Time you go to
home and
desired
overnight
temperature
temperature
buttons.
buttons.
To
activate,
refer
to
Options
4
0, 2, 4
4
0, 2, 4
4
0, 2, 4
4
0, 2, 4
4
0, 2, 4
2
0, 2, 4
2
0, 2, 4
5
2, 3, 4, 5, 6
10°C
5°C to 28°C
OF / ON
OF / ON
buttons and
8.2
For greater flexibility, you can define the cycle that best suits your
requirements. The shorter the cycles, the greater your comfort.
However, your system will be activated more often when using
shorter cycles.
Cycles/hour
6.
2
3
4
5
6
8.3
Use this menu to modify the Frost Protection setpoint associated with
the Frost Protection mode. The setting range is between 5°C and
28°C. Default: 10°C.
8.4
When Early Start is activated, the TH136 calculates the optimum start
time to obtain the desired temperature by the programmed set time.
bed and
8.5
For hot water installations, it is recommended that the pump be
activated at least 15 seconds every 24 hours to avoid any seizing.
Technical Specifications
7.
Power
supply: 2 AAA (LR03) alkaline batteries
Max. resistive
Max. inductive
Remote
input: 12 VDC / ± 10% / 5 mA
Control
device: Electronic
Automatic
Storage
Operating
condensation
Temperature setpoint
Temperature setpoint
Temperature display
Temperature display
Software: Class A
Protection
Environment: normally polluted
Warranty
Advanced
Aube warrants this product, excluding battery (if applicable), to be free from defects in the
workmanship or materials, under normal use and service, for a period of three (3) years
from the date of purchase by the consumer. If at any time during the warranty period the
8.
product is determined to be defective or malfunctions, Aube shall repair or replace it (at
Aube's option).
If the product is defective,
(i)
return it, with a bill of sale or other dated proof of purchase, to the place from which
you purchased it, or
(ii)
contact Aube. Aube will make the determination whether the product should be
returned, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall not
apply if it is shown by Aube that the defect or malfunction was caused by damage which
occurred while the product was in the possession of a consumer.
Aube's sole responsibility shall be to repair or replace the product within the terms stated
above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND,
INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING,
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS
OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some provinces and
states do not allow the exclusion or limitation of incidental or consequential damages, so
this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS
PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WAR-
RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS
HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some
provinces and states do not allow limitations on how long an implied warranty lasts, so
the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary
from province or state to another.
Technical Assistance
705 Montrichard
Saint-Jean-sur-Richelieu
Québec, Canada J2X 5K8
Tel. : (450) 358-4600
1-800-831-AUBE
Fax : (450) 358-4650
Modify the Heating Cycles (CPH)
Length
30 min.
20 min.
15 min.
Fuel, gas & electrical furnace
12 min.
10 min.
Modify the Frost Protection Setpoint (HLd)
Early Start (ES)
Pump Protection (PP)
load: 5A @ 240 VAC
load: 2A @ 240 VAC
action: Type 1B
temperature: -20°C to 50°C
temperature: 0°C to 50°C, 95% relative humidity without
range: 5°C to 28°C
interval: 0.5°C
resolution: 0.1°C
accuracy: ± 0.3°C
degree: IP 20
10 rue Ampère
95500 Gonesse
France
33 (0) 1 34 07 99 00
33 (0) 1 34 07 99 19
For more information on our products, visit us at
www.aubetech.com
400-136-001-C
Installation
Commercial unit
Commercial unit
Direct wiring to circulator
Direct wiring to circulator
2008-02-01
9.
10.
11.
2/2