Aube Technologies TI070 Посібник користувача

Переглянути онлайн або завантажити pdf Посібник користувача для Перемикач Aube Technologies TI070. Aube Technologies TI070 4 сторінки. 7-day solar programmable wall switch

Aube Technologies TI070 Посібник користувача
Applications
The TI070 programmable wall switch can be used in a single-switch or 3-way installation with the following
types of lighting:
• Incandescent
• Halogen
• Low-voltage halogen with transformer
The TI070 switch cannot be used with a load of less than 40 W or more than 500 W.
Installation
Cut power at the circuit breaker to avoid electric shock.
Remove the existing switch. (For a 3-way installation, identify and label the wire connected to the
"common" screw.)
Install the new switch.
Apply power at the circuit breaker.
WARNING: Disconnect power to the switch when replacing a light bulb (see section 4).
SINGLE-SWITCH INSTALLATION
black
120
VAC
white
white
120
VAC
black
Connect the LINE and 3 WAY wires to the line (120 V) wire and LOAD wire to the load. Connect the GND
wire to a ground screw inside the electrical box.
EXISTING 3-WAY INSTALLATION
black
black
120
VAC
white
jumper
white
black
three-way
switch
Connect the LOAD wire on the TI070 to the "common" wire, which you identified when removing the old
switch. Connect the GND wire to a ground screw inside the electrical box. Connect the LINE and 3 WAY
wires to the two remaining wires. At the other 3-way switch, connect the jumper wire between the "common"
screw and the screw where the LINE wire of the TI070 is connected.
NEW 3-WAY INSTALLATION
black
black
120
VAC
white
white
TI070
• Fluorescent
black
white
black (LOAD)
green (GND)
black (LINE)
purple (3 WAY)
black
white
black (LOAD)
green (GND)
black (LINE)
purple (3 WAY)
black (LOAD)
green (GND)
black (LINE)
purple (3 WAY)
white
red
black (LOAD)
green (GND)
black (LINE)
purple (3 WAY)
white
black
1.
Quick Start-up
Set the time and date before using the switch for the first time.
The TI070 will turn the lights on at sunset and turn them off at 11:00 pm by default. If these settings are
appropriate for you, you only need to set the time and date (see shaded zone in programming flowchart).
The switch is now ready to go.
2.
Operation
Indicates the mode of
operation (see Section 5.1)
Indicates the time and day
Indicates the current program
Indicates the load on/off state
Briefly press this button to turn the
lights on or off. See "Temporary
Override" in Section 5.1.4.
Before replacing a light bulb, pull out to disconnect power to the switch.
This prevents, while the bulb is out, any possible short circuit which will
damage the switch. Push back in after the light bulb is replaced.
Programming
5.1
Mode Menu
You can use the Mode menu to select one of the three modes of operation (see sections 5.1.1 to 5.1.3).
5.1.1 Manual Mode
In Manual mode, the TI070 operates like a regular switch. To turn the lights on or off, briefly
press the main button. The
5.1.2 Automatic Mode
In Automatic mode, the TI070 turns the lights on or off according to the set programs (see
Section 5.4). The
icon as well as the current program number are displayed.
5.1.3 Random Mode
In Random mode, the TI070 has no specific times to turn the lights on or off. This mode is
designed to give the impression the house is occupied during your absence. It is similar to
the Automatic mode except there is no fixed program. The programs are automatically set
to different times by the TI070 every day. The
Random mode.
The first "On" program occurs at sunset. Each "On" program lasts between 1 hour and 1
hour and 30 minutes; each "Off" program lasts between 15 and 30 minutes. The last "Off"
program occurs between 10:30 pm and midnight.
5.1.4 Temporary Override
When the TI070 is in Automatic or Random mode, you can press the main button at any time to override the
default state for the current program. The light will turn off if they are on and vice versa. The icon (On or Off)
of the new state flashes to indicate that the state is temporary. The new state is maintained until you press
the main button again or till the next "On" or "Off" program.
single-pole
switch
7-day Solar Programmable Wall Switch
The
icon indicates the current program
has been activated at sunset.
The
icon indicates the current program
has been activated at sunrise.
You can change the mode of operation by
pressing this button for 1 second.
The LED illuminates when the load state is on.
Safety switch
Refer to the programming flowchart.
icon appears when the switch is in Manual mode.
icon appears when the switch is in
400-070-000-A
TI070
User guide
3.
4.
5.
2007-12-13