AUBER INSTRUMENTS

5.3 Boiling Operation

When first powered up, make sure the controller is in the boiling mode: the
mashing mode indicator on the upper left corner is off and bottom display has a
"P" on the left. If not, change the control mode to boiling mode as discussed in
section 5.1 above. If you were using the controller in the boiling mode when
powered off last time, the controller will start in boiling mode.
The top LED displays the current temperature reading from the sensor. If
temperature sensor is not connected, it will show orAL. The controller will not
turn on the heater if the sensor is not connected. The bottom LED displays the
boiling output in percentage of the power. For example, if you use a 5500
Watts heater, "P50" mean the heater is running at 50% of power, or 2750
Watts (5500x50%=2750). The symbol "P" on the left is for making sure that the
display does not get confused with temperature setting of the mashing mode.
You can rotate the knob to adjust the output value. The new setting will take
effect automatically. There is no need to push the knob to confirm as the
temperature setting change in the mashing mode. For the first time use, while
the controller is still in the acceleration phase, you should set the boiling output
to a value below 60%. Once the controller finished the acceleration, it will
switch to this power level automatically. After getting familiar with your system,
you can set to a higher value that produce a rolling boil without boiling over.
When the controller is powered up, the output indicator will stay on solid. This
mean the controller is in the acceleration phase. Once the temperature rise
above the acceleration phase, the power output will be reduced to the value as
shown on the bottom display. The Output indicator will start to flash at slower
rate.
Note, when adjusting the boiling output setting while the controller is still in the
acceleration phase, the new setting will be shown on the bottom display.
However, it will not take effect until the acceleration phase is finished. If you want
to manually control the power output during the entire boiling process, set bAST
to zero (see section 6.3 for details).
For how to set up the boiling mode, please read section 6.3.

6. Control Parameters

Parameters are divided into three groups (figure 5): MASH for mashing control,
BOIL for boiling control, and SYST for system configuration. The same type of
parameter may have slightly different names when used in different mode. For
example, the timer setting in mashing mode is called "t", while this parameter is
called "bt" in the boiling mode.
To enter parameter setting mode, press and hold the knob for at least 5s. Then
you will see "GOTO" on the top display. Rotate the knob, you will see the bottom
display changes with three different names: MASH (for mashing parameters,
figure 7), BOIL (for boiling parameters, figure 8) and SYST (for system settings,
figure 6). The parameter values are stored in the controller memory. All the
settings remain unchanged if you power it off.
Push the dial to enter the selected parameter group. Then top display shows the
current selected parameter name, and the bottom display shows its
value/options. Rotate the knob clockwise to increase the value, and rotate it
counter-clockwise to reduce the value. Faster rotating speed will change the
value rapidly. Once finished, press knob again to confirm and go to next
parameter. You can press the knob repeatedly to exit the setting quickly.
2017.03
80
100
Press down
Knob
and hold t he
knob for 5s
goto
mash
Rotate
Knob
goto
boil
Rotate
Knob
goto
syst
Figure 5. Parameter group selection

6.1 System settings

Parameters that are shared by both control modes are under this group.
Table 1. System configuration parameters
System Configuration
Display
Code
Description
tF
Timer function
tF
tdIr
Timer counting direction
tdIr
Temperature reading
Pb
Pb
offset
C-F
Temp. display unit
C-F
Note 1. Timer settings. tF, tdIr
tF: The timer function is controlled by a master parameter tF. When it is set to
ON, the timer function (for both mashing and boiling modes) is enabled. When
tF is set to OFF, the timer function is disabled.
tdIr: Timer direction parameter. Set it to up for timer counting up and dn for timer
counting down.
Note 2. Input offset. Pb
Pb is used to set an input offset to compensate the error produced by the sensor
or input signal itself. For example, if the controller displays 2ºC when probe is in
ice/water mixture, setting Pb = -2, will make the controller display 0ºC.
Note 3. Temperature unit setting. C-F
C-F determines the temperature unit. It can be set to C (Celsius, ˚C) or F
(Fahrenheit, ˚F).
WWW.AUBERINS.COM
Knob
Enter Mash
mode settings
Press
Knob
Enter Boil
mode settings
Press
Knob
Enter System
settings
Press
Setting
Initial
Range
Setting
ON, OFF
ON
dn, uP
dn
-100~+100 ° C
0
or ° F
° C, ° F
° F
Remark
Note 1
Note 2
Note 3
P3/9